| Rated Output Current (A) | Ultra light load: 46, light load: 40, standard load: 32 |
| Mass (Kg) | 6 |
| Motor Capacity | Ultra-light load: 11 kW, light load: 11 kW, standard load: 7.5 kW (4 poles) |
| Protection Class | IP20/UL |
Rated Output Current (A) |
Ultra light load: 46, light load: 40, standard load: 32 |
Mass (Kg) |
6 |
Motor Capacity |
Ultra-light load: 11 kW, light load: 11 kW, standard load: 7.5 kW (4 poles) |
Protection Class |
IP20/UL |
Monotaro ID |
33134719 |
Rated Output Capacity (kVA) |
[200V] Ultra-light load: 15.9, Light load: 13.8, Standard load: 11 [240V] Ultra-light load: 19.1, Light load: 16.6, Standard load: 13.3 |
Type of Product |
Inverter |
Model No |
P1-075LFF |
Dimension (mm) |
260Hx210Wx170L |
Country of Origin |
Japan |
Import Country |
Direct Import from Japan |
Output Frequency (Hz) |
0 to 590 |
Storage Temperature |
-20 to 65℃ |
Type |
P1 |
Control |
PWM method |
Name of Manufacturer/Packer/Importer |
Hitachi Industrial Systems Co., Ltd. |
Rated Input Voltage (V) |
Main circuit power supply: Three-phase (3-wire) AC 200 to 240 50Hz/60Hz, Control power supply: Single-phase AC 200 to 240 50Hz/60Hz |
Paint Color |
Black |
Applicable Standard |
CE: EN IEC 61800-3:2018 Second environment, Category C3・EN 61800-5-1:2007, EN 61800-5-1:2007/A1:2017・EN 61800-5-1:2007/A11:2021・EN 61800-9-2:2017, EN IEC 63000: 2018・UL: UL 61800-5-1, 1st Ed., Issue Date 2012-06-08, Revision Date 2021-02-11, -Overvoltage Category 3, -Pollution Degree 2・Other: c-UL C22.2 No.274, 2nd Ed., Issue Date 2017-04-01, RCM AS NZS 4417.2 2020 |
Service Life |
Main circuit smoothing capacitor design life: 10 years, cooling fan design life: 10 years (models with cooling fan), operation panel (VOP) LCD backlight design life: 10 years (8 hours a day, 100% dimming, 30% brightness reduction) However, there must be no dust. |
Options |
Braking resistors, AC reactors, DC reactors, noise filters, cables for LCD control panels, harmonic suppression units, noise filters, LCR filters, analog control panels, regenerative braking units, power regeneration converters, PC setting software ProDriveNext |
Overload Current Rating |
Ultra light load: 110% 60sec / 120% 3sec, Light load: 120% 60sec / 150% 3sec, Standard load: 150% 60sec / 200% 3sec |
Acceleration / Braking Time |
0 to 3600sec (straight line, S-shape, U-shape, inverted U-shape, EL-S-shape) |
AC Voltage Tolerance (V) |
170 to 264 50Hz/60Hz(±5%) |
Other functions |
V/f free setting (7 points), upper and lower frequency limiters, frequency jump, curved acceleration/deceleration, manual torque boost, energy-saving operation, analog output adjustment function, minimum frequency, carrier frequency adjustment, motor electronic thermal function (free setting also possible), inverter electronic thermal function, external start/end, frequency input selection, trip retry, restart after momentary power failure, various signal outputs, initialization setting, PID control, automatic deceleration at power interruption, brake control function, commercial switching function, auto-tuning (on/offline), etc. |