Lab-Junction Cod Digester

Showing 3 out of 3 products

Sort by
₹99,119  
Lab Junction 12 Tubes COD Digestion Apparatus for Laboratories LJ-070 is a laboratory instrument used for the determination of the chemical oxygen demand in water and wastewater samples. The chemical oxygen demand is a measure of the amount of organic pollutants present in a sample that can be oxidized by a strong chemical oxidant.
The COD digestion apparatus consists of a heating block or a set of digestion tubes specifically designed to withstand high temperatures. The apparatus utilizes a strong oxidizing agent, typically a mixture of potassium dichromate (K2Cr2O7) and sulfuric acid (H2SO4), to oxidize the organic compounds present in the sample.
The process begins by adding the water or wastewater sample into the digestion tubes or vessels. The appropriate amount of the oxidizing agent is then added to the sample. The digestion tubes are sealed to prevent any loss of volatile compounds during the process. The tubes are then placed in the heating block, which is preheated to a specific temperature, typically around 150-165 degrees Celsius.
During the digestion process, the strong oxidizing agent reacts with the organic compounds in the sample, converting them into carbon dioxide (CO2) and water (H2O). This reaction is facilitated by the high temperature and the presence of the sulfuric acid catalyst. The heating block maintains a constant temperature throughout the digestion period, which is typically around 2 hours.
After digestion, the tubes are removed from the heating block and allowed to cool. The resulting solution is then ready for further analysis. The COD level in the sample is determined by titration or colorimetric methods, where a reagent is added to the digested sample to measure the amount of residual oxidizing agent or the color intensity formed due to the reaction.
The COD digestion apparatus offers several advantages in COD determination. It provides a controlled and standardized method for the digestion process, ensuring consistent and reliable results. The high temperature and strong oxidizing agent ensure the complete oxidation of organic compounds, allowing for accurate measurement of the COD level. The apparatus is also designed to handle multiple samples simultaneously, making it efficient for high-throughput analysis.
In summary, the COD digestion apparatus is a specialized laboratory instrument used for the determination of chemical oxygen demand in water and wastewater samples. It utilizes a high-temperature digestion process with a strong oxidizing agent to oxidize organic compounds present in the sample. The apparatus provides a controlled and standardized method for COD determination, enabling accurate assessment of the organic pollutant levels in water and wastewater samples.
₹1,13,279  
Lab Junction 15 Tubes COD Digestion Apparatus for Laboratories LJ-071 is a laboratory instrument used for the determination of the chemical oxygen demand in water and wastewater samples. The chemical oxygen demand is a measure of the amount of organic pollutants present in a sample that can be oxidized by a strong chemical oxidant.
The COD digestion apparatus consists of a heating block or a set of digestion tubes specifically designed to withstand high temperatures. The apparatus utilizes a strong oxidizing agent, typically a mixture of potassium dichromate (K2Cr2O7) and sulfuric acid (H2SO4), to oxidize the organic compounds present in the sample.
The process begins by adding the water or wastewater sample into the digestion tubes or vessels. The appropriate amount of the oxidizing agent is then added to the sample. The digestion tubes are sealed to prevent any loss of volatile compounds during the process. The tubes are then placed in the heating block, which is preheated to a specific temperature, typically around 150-165 degrees Celsius.
During the digestion process, the strong oxidizing agent reacts with the organic compounds in the sample, converting them into carbon dioxide (CO2) and water (H2O). This reaction is facilitated by the high temperature and the presence of the sulfuric acid catalyst. The heating block maintains a constant temperature throughout the digestion period, which is typically around 2 hours.
After digestion, the tubes are removed from the heating block and allowed to cool. The resulting solution is then ready for further analysis. The COD level in the sample is determined by titration or colorimetric methods, where a reagent is added to the digested sample to measure the amount of residual oxidizing agent or the color intensity formed due to the reaction.
The COD digestion apparatus offers several advantages in COD determination. It provides a controlled and standardized method for the digestion process, ensuring consistent and reliable results. The high temperature and strong oxidizing agent ensure the complete oxidation of organic compounds, allowing for accurate measurement of the COD level. The apparatus is also designed to handle multiple samples simultaneously, making it efficient for high-throughput analysis.
In summary, the COD digestion apparatus is a specialized laboratory instrument used for the determination of chemical oxygen demand in water and wastewater samples. It utilizes a high-temperature digestion process with a strong oxidizing agent to oxidize organic compounds present in the sample. The apparatus provides a controlled and standardized method for COD determination, enabling accurate assessment of the organic pollutant levels in water and wastewater samples.
₹93,219  
Lab Junction 6 Tubes COD Digestion Apparatus for Laboratories LJ-069 is a laboratory instrument used for the determination of the chemical oxygen demand in water and wastewater samples. The chemical oxygen demand is a measure of the amount of organic pollutants present in a sample that can be oxidized by a strong chemical oxidant.
The COD digestion apparatus consists of a heating block or a set of digestion tubes specifically designed to withstand high temperatures. The apparatus utilizes a strong oxidizing agent, typically a mixture of potassium dichromate (K2Cr2O7) and sulfuric acid (H2SO4), to oxidize the organic compounds present in the sample.
The process begins by adding the water or wastewater sample into the digestion tubes or vessels. The appropriate amount of the oxidizing agent is then added to the sample. The digestion tubes are sealed to prevent any loss of volatile compounds during the process. The tubes are then placed in the heating block, which is preheated to a specific temperature, typically around 150-165 degrees Celsius.
During the digestion process, the strong oxidizing agent reacts with the organic compounds in the sample, converting them into carbon dioxide (CO2) and water (H2O). This reaction is facilitated by the high temperature and the presence of the sulfuric acid catalyst. The heating block maintains a constant temperature throughout the digestion period, which is typically around 2 hours.
After digestion, the tubes are removed from the heating block and allowed to cool. The resulting solution is then ready for further analysis. The COD level in the sample is determined by titration or colorimetric methods, where a reagent is added to the digested sample to measure the amount of residual oxidizing agent or the color intensity formed due to the reaction.
The COD digestion apparatus offers several advantages in COD determination. It provides a controlled and standardized method for the digestion process, ensuring consistent and reliable results. The high temperature and strong oxidizing agent ensure the complete oxidation of organic compounds, allowing for accurate measurement of the COD level. The apparatus is also designed to handle multiple samples simultaneously, making it efficient for high-throughput analysis.
In summary, the COD digestion apparatus is a specialized laboratory instrument used for the determination of chemical oxygen demand in water and wastewater samples. It utilizes a high-temperature digestion process with a strong oxidizing agent to oxidize organic compounds present in the sample. The apparatus provides a controlled and standardized method for COD determination, enabling accurate assessment of the organic pollutant levels in water and wastewater samples.
Recommended Items
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
sku-leadTime Ships within 2 days
14
Pack of 10 ream
₹2,005 ₹2,005
0.01% OFF
sku-leadTime Ships within 10 days
oos-available Ships within 24 hrs
sku-leadTime Ships within 10 days
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
Browsing History
sku-leadTime Ships within 5 days
sku-leadTime Ships within 7 days
sku-leadTime Ships within 3 days
sku-leadTime Ships within 7 days
sku-leadTime Ships within 10 days
sku-leadTime Ships within 6 days
₹44,099 ₹54,600
19.23% OFF