Filter

Categories
Price Range
Min Price:
Max Price:
-
Discount
Type of Product

Milwaukee Tds Meter

Showing 4 out of 4 products

Sort by
₹34,219   ₹34,810
You save ₹591!
1.7% OFF
Mi150 is an advanced pH/Temp microprocessor-based bench meter. It is ideal for students and technicians who need fast and reliable measurements.
This meter is provided with a series of new diagnostic features which add an entirely new dimension to the measurement of pH, by allowing the user to dramatically improve the reliability of the measurement:
Automatic Temperature Compensation (ATC) for good accuracy under fluctuating temperatures
Easy to read large custom LCD
Easy and Quick Push-button Calibration
7 memorized buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45) for calibration
Messages on the LCD to make the calibration easy and accurate
User-selectable “calibration time out” to remind when a new calibration is necessary
Stability Indicator prompts whenever reading stabilizes.
Moreover, it offers an extended temperature range from –20°C (–4°F) to 120°C (248°F),using the MA831R interchangeable temperature probe.
Untitled Document
.tableSpecification {
border-collapse: collapse;
}
.tableSpecification td {
border: 1px solid #000000;
padding: 8px;
text-align: left;
Temp Resolution
0.1°C / 0.1 °F
Temp Accuracy
±0.4°C / ±0.8°F
pH Typical EMC Deviation
±0.02 pH
Temp Typical EMC Deviation
±0.4°C / ±0.8°F
pH Automatic Calibration
1 or 2 point-calibration, with 7 memorized buffers
Offset Calibration
±1 pH
Slope Calibration
from 80 to 108%
Temperature Compensation
automatic, from -20.0 to 120.0°C /
-4.0 to 248.0°F or manual, without temperature probe
pH Electrode
MA917B/1 (included)
Temperature Probe
MA831R (included)
Environment
0 to 50°C / 32 to 122°F; max RH 95%
Input Impedance
1012 Ohm
₹89,679   ₹92,630
You save ₹2,951!
3.19% OFF
Mi180 pH / ORP / Conductivity / TDS / NaCl / Temperature Laboratory Bench Meter
Mi180 measures 6 different parameters: pH, ORP, EC, TDS (Total Dissolved Solids), percentage of NaCl and temperature in a variety of ranges.
pH calibration can be performed in 3 points selectable between 7 memorized buffers, to provide a very accurate calibration curve even when testing different samples, where very wide differences in pH can be found.
The auto-ranging feature for EC and TDS measurements automatically sets the resolution suitable to the tested sample.
All measurements can be temperature compensated at 20 or 25°C and the compensation coefficient is selectable by the user.
The automatic temperature compensation can also be disabled for measuring the actual conductivity value. The stability indicator on the LCD ensures accuracy. Conductivity readings are performed with the 4-ring probe supplied with the meter.
The GLP feature allows users to store and recall data on system status. PC compatible through an RS232 port or USB.
Untitled Document
.tableSpecification {
border-collapse: collapse;
}
.tableSpecification td {
border: 1px solid #000000;
padding: 8px;
text-align: left;
pH Range
-2.00 to 16.00 pH; -2.000 to 16.000 pH
mV Range
±699.9 mV; ±2000 mV
EC Range
0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm
3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm uncompensed EC*
TDS Range
0.0 to 14.99 mg/l (ppm); 15.0 to 149.9 mg/l (ppm); 150 to 1499 mg/l (ppm)
1.50 to 14.99 g/l (ppt); 15.0 to 100.0 g/l (ppt); up to 400.0 g/l actual TDS* (with 0.80 factor)
NaCl Range
0.0 to 400.0%
Temp Range
-20.0 to 120.0°C / -4.0 to 248.0°F
pH Resolution
0.01 pH; 0.001 pH
mV Resolution
0.1 mV; 1 mV
EC Resolution
0.01 µS/cm; 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm;
TDS Resolution
0.01 mg/l; 0.1 mg/l; 1.0 mg/l; 0.01 g/l; 0.1 g/l
NaCl Resolution
0.1%
Temp Resolution
0.1°C / 0.1°F
pH Accuracy
±0.01 pH; ±0.002 pH
mV Accuracy
±0.2 mV; ±1 mV
EC Accuracy
±1% of reading ±(0.05 µS/cm or 1 digit)
TDS Accuracy
±1% of reading ±(0.03 ppm or 1 digit)
NaCl Accuracy
±1% of reading
Temp Accuracy
±0.4°C / ±0.8°F
Rel mV Offset
±2000 mV
pH Calibration
1, 2 or 3 points calibration, with 7 memorized buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45)
EC Calibration
1 point slope calibration with 6 memorized solutions
(84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 µS/cm, 80.0 µS/cm, 111.8 mS/cm)
NaCl Calibration
1 point, with MA9066 solution
Temp Calibration
2 point, at 0 and 50°C / 32 and 122°F
Temperature Compensation
automatic or manual, from -20.0 to 120.0°C / -4.0 to 248.0°FF
Temperature Coefficient
selectable from 0.00 to 6.00%/°C (EC and TDS only)
pH Electrodes & Temp Probe
MA814DB/1 & MA917B/1 & MA831R (included)
TDS Factor
0.40 to 0.80 (default value is 0.50)
Log on demand
up to 50 samples on each range (pH, mV, EC, TDS, NaCl)
GLP
last pH, EC, NaCl calibration data
PC Interface
RS232 / USB Opto-isolated
Environment
0 to 50°C / 32 to 122°F; max RH 95%
₹1,29,799  
Mi190 Dissolved Oxygen / Temperature Laboratory Bench Meter
Ideal for testing Dissolved Oxygen in the pharmaceutical and food Industry, as well as monitoring in water treatment plants. The user can choose to measure D.O. readings in mg/L or % of saturation of O2.
This meter can be used for any type of water, as it allows measurements to compensate for temperature, altitude and salinity factors. The automatic logging interval can be set to perform analysis and store data into the memory.
All logged data can be downloaded to your PC through an RS232 or USB serial port. Memory can store up to 50 samples.
Mi190 features an automatic calibration procedure, at 1 or 2 points (at 0 and 100% of O2 saturation). The polarographic probe supplied with the meter (MA840/2) measures the current generated by the reaction of O2 with Ag.
Mi190 is supplied complete with MA840/2 DO probe with 2 m cable, 2 spare membranes, MA7041 electrolyte solution (30 mL), 12 VDC power adapter, probe holder and instruction manual.
Untitled Document
.tableSpecification {
border-collapse: collapse;
}
.tableSpecification td {
border: 1px solid #000000;
padding: 8px;
text-align: left;
O2 Range
0.00 to 45.00 mg/l (ppm)
% Saturation O2 Range
0.0 to 300%
Temp Range
-5.0 to 55.0°C / 23.0 to 131.0°F
O2 Resolution
0.01 mg/l (ppm)
% Saturation O2 Resolution
0.001
Temp Resolution
0.1°C / 0.1°F
O2 Accuracy
±1.5 Full Scale
% Saturation O2 Accuracy
±1.5 Full Scale
Temp Accuracy
±0.4°C / ±0.8°F
Logging
50 records, LOG on demand or auto-logging
DO Calibration
automatic, 1 or 2 point at 0% (MA9070) and 100% (in air)
Temperature Compensation
0.0 to 50.0°C / 32.0 to 122.0°F
Altitude Compensation
0 to 4000 m; resolution 100 m
Salinity Compensation
0 to 40 g/L; resolution 1 g/L
DO Probe
MA840/2 with DIN connector (included)
Temperature Probe
Included in DO probe
Calibration
2 points (0.0°C and 50.0°C / 32.0 to 122.0°F)
Log on demand
up to 50 records
PC Interface
RS232 / USB Opto-isolated
Environment
0 to 50°C / 32 to 122°F; max RH 95%
₹71,979   ₹73,750
You save ₹1,771!
2.4% OFF
Mi170 Autoranging Conductivity / TDS / NaCl / Temperature Laboratory Bench Meter
Mi170 measures 4 different parameters - EC, TDS (Total Dissolved Solids), percentage of NaCl and temperature in a variety of ranges.
The auto-ranging feature for EC and TDS measurements automatically sets the resolution suitable to the tested sample. All measurements can be temperature compensated at 20 or 25°C and the compensation coefficient is selectable by the user.
The automatic temperature compensation can also be disabled for measuring the actual conductivity value. The stability indicator on the LCD ensures accuracy.
Conductivity readings are performed with the 4-ring probe supplied with the meter. The GLP feature allows users to store and recall data on system status.
PC compatible through an RS232 or USB port.
Untitled Document
.tableSpecification {
border-collapse: collapse;
}
.tableSpecification td {
border: 1px solid #000000;
padding: 8px;
text-align: left;
EC Range
0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm
3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm actual Conductivity*
TDS Range
0.00 to 14.99 mg/l (ppm); 15.0 to 149.9 mg/l (ppm); 150 to 1499 mg/l (ppm)
1.5 to 14.99 g/l (ppt); 15.0 to 100.0 g/l (ppt); up to 400.0 g/l actual TDS* (with 0.80 factor)
NaCl Range
0.0 to 400.0%
Temp Range
-20.0 to 120.0°C / -4.0 to 248.0°F
EC Resolution
0.01 µS/cm; 0.1 µS/cm; 1.0 µS/cm; 0.01 mS/cm; 0.1 mS/cm
TDS Resolution
0.01 mg/l; 0.1 mg/l; 1.0 mg/l; 0.01 g/l; 0.1 g/l
NaCl Resolution
0.1%
Temp Resolution
0.1°C / 0.1 °F
EC Accuracy
±1% of reading ±(0.05 µS/cm ro 1 digit)
TDS Accuracy
±1% of reading ±(0.03 mg/l or 1 digit)
NaCl Accuracy
±1% of reading
Temp Accuracy
±0.4°C / ±0.8°F
EC Calibration
1 point slope calibration with 6 memorized solutions
(84.0 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)
NaCl Calibration
1 point, with MA9066 calibration solution
Temp Calibration
2 points, 0 to 50°C / 32 to 12 °F
Temp. Compensation
automatic or manual, from -20.0 to 120.0°C / -4.0 to 248.0°F
Temp. Coefficient
selectable from 0.00 to 6.00%/°C (EC and TDS only)
Probe
MA813D/1 4-ring probe with built-in temperature sensor (included)
TDS Factor
0.40 to 0.80 (default value is 0.50)
Log on Demand
up to 50 samples on each range (EC, TDS, NaCl)
GLP
last EC, NaCl calibration data
PC Interface
RS232 / USB Opto-isolated
Environment
0 to 50°C / 32 to 122°F; max RH 95%
Recommended Items
sku-leadTime Ships within 10 days
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
Browsing History
sku-leadTime Ships within 5 days
sku-leadTime Ships within 7 days
sku-leadTime Ships within 3 days
sku-leadTime Ships within 7 days
sku-leadTime Ships within 10 days
sku-leadTime Ships within 6 days
₹44,099 ₹54,600
19.23% OFF

Top Selling Milwaukee Tds Meter Products Price List for March 2026

This data was last updated on 18/03/2026