| Type of Product | Digital Storage Oscilloscope |
| Model No | DCS-2102E |
| Waveform | (Save) 24 sets |
| Input Impedance | 1MΩ // Approximately 16pF |
Type of Product |
Digital Storage Oscilloscope |
Model No |
DCS-2102E |
Waveform |
(Save) 24 sets |
Input Impedance |
1MΩ // Approximately 16pF |
Interface |
(Ethernet port) RJ-45, 10/100Mbps, HP Auto-MDIX function support, remote disk function, (anti-theft lock) Standard Kensington style lock can be connected to the anti-theft slot on the back panel |
Input Coupling |
AC, DC, GND |
No. of Channels |
2ch |
Resolution |
8-bit |
Country of Origin |
Japan |
Monotaro ID |
20341703 |
Sensitivity |
1 mV/div, 1 to 10V/div |
Import Country |
Direct Import from Japan |
Measurement |
Voltage difference ΔV (current difference ΔA) between cursors, time difference (ΔT) between cursors, and during FFT: frequency and amplitude (dB or V). |
Name of Manufacturer/Packer/Importer |
Texio Technology Co., Ltd. |
Time |
Frequency, period, rise time, fall time, + width,-width, duty ratio, + pulse, -pulse, + edge, -edge |
Maximum Input Voltage |
300V rms, CAT I |
Accept/Reject Output |
(Go-NoGo / Terminal) BNC female, maximum 5V / 10mA TTL open collector output |
Control Function |
(Panel) Autoset: Automatically sets the vertical and horizontal scales and trigger levels for all channels. Autoset is undoable. |
Function |
Segment memory: Acquires up to 29,000 waveforms per trigger (memory length: 1K points). Waveform search: Sets and searches up to 10,000 marks on waveforms based on search conditions. FFT peak search: Displays up to 10 maximum peaks. Thresholds can be set. Peak events (frequency, amplitude) can be displayed in a list. The list can be saved to USB as a CSV file. Scale display: Displays the scale on the right side of the screen when the dBV scale is selected. Digital voltmeter: 3-digit voltmeter: ACV rms, DCV, DCV rms, 5-digit frequency counter. Digital filter: Low-pass and high-pass filters can be set per channel or linked to each channel. Range: 1Hz to 500MHz. Data log function: Records waveform data or screen images to USB memory or remote disk (via LAN) at set intervals for a set time. Time: 2 seconds to 2 minutes (waveform data), 5 seconds to 2 minutes (screen image), 5 minutes to 100 hours. |
Specifications |
Cursor / Amplitude, Time, With gate function (at the time of automatic measurement) Unit: Second (s), Hz (1 / s), Phase (°), Ratio (%), Automatic measurement / 36 items: Up to 8 items at the bottom of the screen Simultaneous display up to, Gating function: Any part of the captured waveform can be specified with the cursor, Statistics: Average, maximum, minimum, deviation can be displayed with maximum 1000 data, voltage current / pp value, maximum value, minimum value , Amplitude, high value, low value, average, cycle average, RMS, cycle RMS, area, cycle area, ROV shoot, FOV shoot, RPRE shoot, FPR shoot, save panel settings / 20 sets |
Polarity |
Normal, inverted |
Mass (Kg) |
About 2.8 |
Sampling |
Up to 1GS / s |
USB Ports |
USB 2.0 high-speed host port x 1: Save / recall or print-USB 2.0 high-speed device port x 1: PC control |
Calculation Factor |
+, -, ×, ÷, FFT, FFTrms, User-defined operations, Source CH: CH1 to CH4, Ref1 to Ref4, (FFT) Displays the spectrum amplitude of the selected CH, Vertical scale: Can be set to linear RMS or dBVrms, Horizontal scale: Changeable, Vertical/horizontal position: Settable, FFT window: Selectable from square, Hamming, Hanning, Blackman, FFT waveform memory length: Maximum 1M points <when waveform memory: 10M points>, (Definition) Integral, Differential, log, Ln, Exp, Sqrt, Abs, Rad, Deg, Sin, Cos, Tan, Asin, Acos, Atan |
Limitation |
70MHz model: 20MHz BW, 100MHz model: 20MHz, 70MHz BW, 200MHz model: 20MHz, 70MHz, 100MHz BW |
Offset |
(Position) 1mV / div to 20mV / div: ± 0.5V, 50mV / div to 200mV / div: ± 5V, 500mV / div to 2V / div: ± 25V, 5V / div to 10V / div: ± 250V |
Included Components |
User manual CD, power cord, probe (for the number of channels) |
Language Display |
Japanese, English and others can be used |
Environmental Conditions to Use |
0°C to 50°C, relative humidity ≤ 80% (at 40°C or below), relative humidity ≤ 45% (at 41°C to 50°C) |
Dimension (WxDxH) |
384x208x127.3 mm |
RoHS Directive |
Correspondence |
Delay Time |
FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF, phase |
Frequency Band (MHz) |
DC to 100(-3dB) |
Power Consumption (W) |
30 |
Power Supply Voltage |
AC 100 V to 240 V, 50 Hz to 60 Hz |