| Type | AC clamp compatible (sold separately) |
| Type of Product | Digital Multimeter |
| Model No | DT4253 |
| Storage Temperature Range | -30 to 60 ℃ |
Type |
AC clamp compatible (sold separately) |
Type of Product |
Digital Multimeter |
Model No |
DT4253 |
Storage Temperature Range |
-30 to 60 ℃ |
LCD Display |
4-digit LCD display, max.6000dgt., Bar graph |
Operating Temperature Range |
-10 to 50 ℃ |
Country of Origin |
Japan |
Power Supply |
Requires 4 AAA alkaline batteries (LR03). Continuous usage time: 130 hours (backlight off). |
Frequency |
AC V/AC A: 3 ranges from 99.99 Hz (above 5 Hz) to 9.999 kHz; AC V only: 99.99 kHz; Basic accuracy: ±0.1% rdg. ±1 dgt. |
Resistance |
600Ω to 60MΩ, 6 ranges, basic accuracy: ±0.7%rdg. ±5dgt. |
Resistance (Ω) |
600/6k/60k/600k/6M/60M Basic accuracy ±0.7%rdg.±5dgt. |
Capacitance |
1μF to 10mF, 5 ranges, basic accuracy: ±1.9%rdg. ±5dgt. |
DC current (A) |
60μm to 60m, 4 ranges, basic accuracy: ±0.8% rdg. ±5 dgt. |
Temperature Measurement Range |
-40 to 400°C (using optional K-type thermocouple DT4910), plus temperature probe tolerance (using optional K-type thermocouple DT4910) |
AC Current (A) |
10-1000, 7 ranges, basic accuracy: ±0.9% rdg. ±3 dgt. plus AC clamp measurement accuracy (effective value rectification, crest factor 3 or less) |
Continuity Check |
Continuity ON threshold: 25Ω or less (buzzer sounds, red LED lights up), Continuity OFF threshold: 245Ω or more, Response time: 0.5ms or more |
Diode Test |
Open-circuit voltage: 5V or less, Measuring current: 0.5mA, Forward threshold: 0.15V to 1.5V |
Voltage (Dc) |
600 mV/6 V/60 V/600 V/1000 V Basic accuracy ±0.3%rdg.±5dgt. |
Display Update Rate |
5 times / s (capacitance: 0.05 to 5 times / s depending on the measured value, frequency: 1 to 2 times / s) |
AC Voltage (Volts) |
6/60/600/1000 Frequency response: 40Hz to 1kHz. Fundamental accuracy: 40-500Hz: ±0.9% rdg. ±3 dgt. (RMS rectification, crest factor 3 or less) |
Frequency (Hz) |
99.99Hz to 99.99kHz, 4 ranges (limited by minimum sensitivity voltage), basic accuracy: ±0.1%rdg. ±1dgt. |
Included Components |
Test lead L9207-10 x 1, holster x 1, instruction manual x 1, AAA alkaline battery (LR03) x 4 |
Measurement Method |
True RMS method |
Monotaro ID |
62983891 |
Import Country |
Direct Import from Japan |
Name of Manufacturer/Packer/Importer |
HIOKI E.E. CORPORATION |
Height (mm) |
174 |
Length (mm) |
52 |
Width (mm) |
84 |
Mass (g) |
390 (including batteries and holster) |
RoHS Directive |
Correspondence |
Dimension (WxDxH) |
84x174x52 mm |
Safety Standard |
CAT IV 600 V, CAT III 1000 V |
Trusco Part No. |
753-8618 |
Other functions |
Filter, display value hold, auto hold, maximum / minimum / average value display, relative display, auto power save, USB communication (using option) |