| Measurement Method | Voltage injection and current measurement are performed using an integrated clamp to calculate the grounding resistance value (designed for multiple grounding systems where a single grounding line is grounded multiple times; the more grounding electrodes there are, the more accurate the value). |
| Display | LCD, maximum 2000 counts, display refresh rate approximately 2 times/second |
| Type of Product | Earth Resistance Tester |
| Model No | FT6380-50 |
Measurement Method |
Voltage injection and current measurement are performed using an integrated clamp to calculate the grounding resistance value (designed for multiple grounding systems where a single grounding line is grounded multiple times; the more grounding electrodes there are, the more accurate the value). |
Display |
LCD, maximum 2000 counts, display refresh rate approximately 2 times/second |
Type of Product |
Earth Resistance Tester |
Model No |
FT6380-50 |
Power Supply |
AA alkaline batteries (LR6) x 2 |
Part No |
64-8002-28 |
Country of Origin |
Japan |
Monotaro ID |
62729285 |
Alarm |
[Function] Resistance/Current Alarm: Beeps when below or above the threshold. |
Included Components |
Includes: Carrying case x 1, Test resistors (1Ω, 25Ω) x 1 each, Strap x 1, AA alkaline batteries (LR6) x 2, Instruction manual x 1, Precautions for use x 1 |
Name of Manufacturer/Packer/Importer |
HIOKI E.E. CORPORATION |
Current Range |
20mA (resolution 0.01mA) to 60A (resolution 0.1A), 5 ranges, zero suppression below 0.05mA. |
Import Country |
Direct Import from Japan |
Mass (g) |
Approximately 620 (excluding batteries) |
RoHS Directive |
Correspondence |
Specifications |
Harmonics: [When Z3210 is installed] Harmonic levels/content/total harmonic distortion up to the 30th order in the current (displayable using the application software (GENNECT Cross)) |
Dimension (WxDxH) |
Approximately 73x218x43 mm |
Dust/Water Protection |
IP40 rating, provided the clamp sensor is closed. |
Maximum Rated Voltage |
[To Ground] AC 600 V Measurement Category IV (Expected transient overvoltage 8000 V) |
End To Ground Resistance |
0.2 Ω (resolution 0.01) to 1600 Ω (resolution 20), 10 ranges, zero suppression below 0.02. |
Basic Accuracy |
Grounding resistance range: ±1.5%rdg ±0.02Ω, Current range: ±2.0%rdg ±0.05mA (30Hz to 400Hz, true RMS rectification) |
Continuous Operating Time (hrs) |
Approximately 40 (measured at 25 Ω, backlight off, Z3210 not installed) / Approximately 35 (measured at 25 Ω, backlight off, Z3210 installed, wireless communication in progress) |
Measurable conductor diameter (Φmm) |
32 |
Crest Factor |
5 or less (1.7 or less for the 60 A range) |
Other functions |
Data hold, backlight, filter, auto power save, wireless communication (only when Z3210 is installed) |
Memory Function |
2000 memory storage |
Allowable Current |
[Maximum] AC100 + A continuous, + AC200 + A + 2 minutes + (50 / 60Hz) (with frequency derating) |
Communication Distance |
10 m (only when Z3210 is installed) |