View
View
View
View
| Type of Product | Withstand Voltage Tester |
| Display | VFD: 256 x 64dots + 4STATUS display |
| Measurement Range | (Voltmeter) 0.000kV to 6.500kV AC / DC, (ammeter) AC: 0.00mA to 110mA, DC: 0.00mA to 11mA |
| Model No | TOS5301 |
Type of Product |
Withstand Voltage Tester |
Display |
VFD: 256 x 64dots + 4STATUS display |
Measurement Range |
(Voltmeter) 0.000kV to 6.500kV AC / DC, (ammeter) AC: 0.00mA to 110mA, DC: 0.00mA to 11mA |
Model No |
TOS5301 |
Frequency Range (Hz) |
(Acceptable) 47-63 |
Power Consumption |
No load (READY): 100 VA or less, rated load: 800 VA max. |
Country of Origin |
Japan |
Name of Manufacturer/Packer/Importer |
Kikusui Electronics Co., Ltd. |
Import Country |
Direct Import from Japan |
Monotaro ID |
20217524 |
Included Components |
Power cord x 1, High voltage test lead (TL31-TOS) x 1 set (1 each for red and black, with alligator clip, 1.5m), D-SUB25P plug x 1 Assembly type, High voltage danger seal x 1, User's Manual x 1, CD-R |
Mass (Kg) |
About 15 |
RoHS Directive |
Correspondence |
Frequency (Hz) |
50/60 |
Installation Location |
Indoor, altitude up to 2000m |
Ripple Cotent |
5 kV no-load: 50 Vp-p, maximum rated load: 100 Vp-p |
Insulation Resistance (MOhm) |
Between AC LINE and chassis: 30 or more (500Vdc) |
Outer Dimensions, Width W x Height H x Depth D (mm) |
320 (up to 330) x 132 (up to 150) x 350 (up to 420) |
Output Waveform |
sine wave |
Period |
3 years (at 25 ° C) |
Voltage Fluctuation |
[AC output section] (input) 10% or less (maximum rated load → no load), [DC output section] 3% or less (maximum rated load → no load) |
Guaranteed Performance Temperature and Humidity |
5 ℃ to 35 ℃, 20% rh to 80% rh (no condensation) |
Output |
[AC output section] Range: 0.05kV to 5.00kV, Setting accuracy: ± (2% of set + 20V) [No load], Setting range: 0.00kV to 5.50kV, Setting resolution: 10V STEP, [DC output section ] Range: 0.05kV to 6.00kV, Setting accuracy: ± (2% of set + 20V) [No load], Setting range: 0.00kV to 6.20kV, Setting resolution: 10V STEP |
Withstand Voltage |
Between AC LINE and chassis: 1400Vac, 2 seconds (100% test) / 1500Vac, 1 minute (type test) |
Transformer |
500VA |
Safety |
Low Voltage Directive 2006/95 / EC, EN 61010-1 (Class I, Pollution degree 2) |
Operating Temperature / Humidity Range |
0-40 ℃, 20% rh-80% rh (no condensation) |
Allowable Voltage Range |
AC 90 to 250 V |
EMC Standard to Conform |
EMC Directive 2004/108 / EC, EN 61326-1 (Class A), EN 55011 (Class A, Group 1), EN 61000-3-2, EN 61000-3-3, Applicable conditions: Cables connected to this product and All wires must be less than 2.5 m. When using SIGNAL I / O, use shielded cables. Use high-voltage test leads TL31-TOS. Do not discharge outside the tester. |
Rated Current (mA) |
[AC output unit] Up to 100 (output voltage 0.5 kV or more), [DC output unit] Up to 10 |
Nominal Voltage |
AC 100 to 240 V |
Output fluctuation |
10% or less (maximum rated load → no load) |
Waveform Distortion |
Output voltage 0.5kV or more: 3% or less (no load and pure resistance load) |
Storage Temperature/Humidity Range |
-20 ℃ to 70 ℃, 90% rh or less (no condensation) |
Output Type |
PWM switching method |
Rated Voltage |
[AC output unit] Up to 5, [DC output unit] Up to 6 kV |
Rated Output |
[AC output unit] Maximum 500VA (5kV / 100mA), [DC output unit] Maximum 50W (5kV / 10mA) |
Short Circuit Current |
[AC output unit] 200 mA or more (output voltage 1.0 kV or more), [DC output unit] 40 mA (6 kV output) |
Looking for bulk pricing or different specifications?