View
View
View
View
| Type of Product | Ethernet Switch |
| Power Consumption | <1.01 W @ 24 V DC |
| Operating Temperature | 0 to +55 °C |
| Storage Temperature | -40 to +85 °C |
Type of Product |
Ethernet Switch |
Power Consumption |
<1.01 W @ 24 V DC |
Operating Temperature |
0 to +55 °C |
Storage Temperature |
-40 to +85 °C |
MTBF |
≈ 2860,000 h |
Model No |
24020050010 |
Package Contains |
Pluggable screw contact for power supply & Assembly instructions |
Height |
113.5 mm |
Series |
Ha-VIS eCon 2000 |
Data Rates |
10 Mbit/s & 100 Mbit/s |
Material |
Aluminium (anodised) |
Buffer Size |
Packet 0.44 Megabit |
Width |
46.5 mm |
Flow Control |
Off |
No. of Port |
5 |
Country of Origin |
India |
Transmission Physics |
Twisted Pair Cat. 5 |
Transmission Length |
100 m |
Length |
27.3 mm |
Name of Manufacturer/Packer/Importer |
Harting India Private Limited |
Surge Protection |
Yes |
Conductor Cross Section |
AWG 28 to AWG 12 |
Pinout |
+ / - / FE |
Signal Contact |
No |
Degree of Protection acc. to IEC 60529 |
IP30 mated condition |
Auto-Polarity |
Yes |
Supply |
SELV (Circuit Breaker 10 A) |
Starting Current |
<2.8 A @ 24 V DC & <5.6 A @ 48 V DC |
REACH ANNEX XIV Substances |
Not contained |
Fixing Type |
35 mm DIN rail acc. to EN 60715 |
Air Pressure |
≥795 hPa ≈ 2000 m |
Transmission standard |
10BASE-Te & 100BASE-TX EEE |
Relative Humidity |
0 to 95 % Non-condensing (operation) & 0 to 95 % Non-condensing (storage/transport) |
PoE Functionality |
No |
Number of Contacts A |
3 |
Termination Method |
Pluggable screw contact |
Permissible Voltage |
9 to 60 V DC |
ELV Status |
Compliant |
Frame Size |
1.522 kB |
RoHS |
compliant |
Operating Current |
<42 mA @ 24 V DC & <23 mA @ 48 V DC |
Switching Technology |
Store and Forward |
Auto-MDI(X) |
Yes |
REACH SVHC Substances |
Not contained |
FCC |
Yes |
California Proposition 65 Substances |
Yes |
Auto-Negotiation |
Yes |
Reverse Polarity Protection |
Yes |
Non Blocking |
Yes |
Overcurrent Protection |
2 A at input |
Energie Efficient Ethernet |
Yes |
Quality of Service |
Yes |
REACH Annex XVII Substances |
Not contained |
Ethernet Type |
Fast Ethernet |
Conductor Cross Section Area |
0.08 to 2.5 mm² |
Nominal Voltage |
24 V DC & 48 V DC |