| Model No | KEW6022 |
| Type of Product | Resistance Meter |
| Mass (g) | Approximately 900 (including batteries) |
| Withstand Voltage | AC5320V (50/60Hz)/5 seconds (between electrical circuit and outer box) |
Model No |
KEW6022 |
Type of Product |
Resistance Meter |
Mass (g) |
Approximately 900 (including batteries) |
Withstand Voltage |
AC5320V (50/60Hz)/5 seconds (between electrical circuit and outer box) |
Monotaro ID |
38288853 |
Applicable Standard |
Compliant with JIS C 1302:2014, IEC 61010-1 CAT III 600V, CAT IV 300V Pollution Degree 2, IEC 61010-031 IEC 60529 (IP54) IEC 61557-1, 2, 5, 10 IEC 61326-2-2 |
Country of Origin |
Japan |
Import Country |
Direct Import from Japan |
Name of Manufacturer/Packer/Importer |
Kyoritsu Electrical Instruments Co., Ltd. |
Specifications |
Center display value (insulation resistance tester) / 5MΩ (100V / 125V), 50MΩ (250V / 500V / 1000V) |
RoHS Directive |
Correspondence |
Length (mm) |
133 |
Power Supply |
AA batteries (R6P) x 5 (included) |
Included Components |
7196B (measurement probe with remote switch), 7244A (alligator clip cord set), 8017 (tip metal fitting, long), 8072 (tip metal fitting, standard), 9155 (shoulder strap (with cord belt)), 9156A (soft case), 6 LR6 AA alkaline batteries, instruction manual |
Accuracy |
Insulation resistance meter: (1st effective) ±1.5%rdg±5dgt, (2nd effective) ±5%rdg±6dgt, Earth resistance meter: ±3%rdg±0.1Ω (20Ω range), ±3%rdg±3dgt (200/2000Ω range), Voltmeter: ±1%rdg±4dgt |
Measurement Range |
[Insulation resistance meter] First effective range/insulation resistance measurement: (250V) 1.51-100MΩ, (500V) 1.51-200MΩ, (1000V) 1.51-1000MΩ, Second effective range: (250V) 1.20-1.50MΩ/100.1-2000MΩ, (500V) 1.20-1.50MΩ/200.1-2000MΩ, (1000V) 1.20-1.50MΩ/1001-2000MΩ [Voltmeter] AC5-600V (45-65Hz) DC25-1000V, (Auto range) 20/200/2000Ω (Simple measurement) (Precise measurement) |
Trusco Part No. |
479-6594 |
Effective Measuring Range |
Insulation resistance tester: 100V, 125V/(first effective) 0.1 to 20MΩ, (second effective) 0.11 to 0.19MΩ, 20.01 to 200MΩ, 250V/(first effective) 1.51 to 100MΩ, (second effective) 1.2 to 1.5MΩ, 100.1 to 2000MΩ, 500V/(first effective) 1.51 to 200MΩ, (second effective) 1.2 to 1.5MΩ, 200.1 to 2000MΩ, 1000V/(first effective) 1.51 to 1000MΩ, (second effective) 1.2 to 1.5MΩ, 1001 to 2000MΩ |
Suitable Battery |
AA alkaline batteries LR6 (1.5V) x 6 |
Effective maximum display value |
Auto range: 2/20/200 (100V, 125V), 20/200/2000 (250V, 500V, 1000V) |
Circuit Voltage |
Insulation resistance tester / (open) 1.2 times or less of the rated measured voltage value |
Measurement Method |
Simple measurement (2-pole method) / Precision measurement (3-pole method) |
Dimensions, Length L x Width W x Depth D (mm) |
84x184x133 |
Measuring Current |
(Insulation resistance tester) 1 to 1.2mA DC when a test resistor with a value of rated measurement voltage x 1000Ω is connected |
Measurement Voltage (V) |
(Insulation resistance tester) 100/125/250/500/1000 |
Short Circuit Current |
(Insulation resistance tester) DC1.5 mA or less |
Hardness |
Insulation resistance tester: (1st effective) ±1.5%rdg±5dgt, (2nd effective) ±5%rdg±6dgt Earth resistance tester: ±3%rdg±0.1Ω (20Ω range), ±3%rdg±3dgt ( 200/2000Ω range) Voltmeter: ±1%rdg±4dgt |