View
View
View
View
| Model No | PU21C0122A2N0 |
| Type of Product | Sousatan |
| Rated Current | 10 V |
| Country of Origin | Japan |
Model No |
PU21C0122A2N0 |
Type of Product |
Sousatan |
Rated Current |
10 V |
Country of Origin |
Japan |
Monotaro ID |
41968694 |
Mass (Kg) |
About 2 |
Operating Humidity Range |
30 to 90% Rh (No Condensation) |
Frequency Fluctuation Range (Hz) |
± 2Hz Of Rated Frequency (Performance Guarantee Range Is ± 1Hz) |
Applicable Load |
Resistive Load, Inductive Load (Transformer Primary Side Control, Magnetic Flux Density 1.2T Or Less, Phase Control Only) |
No. of Phases |
Single-Phase |
Load Current (Amp) |
Minimum: 0.5A Or More (At 98% Output Of Rated Voltage) |
Insulation Resistance |
Dc500V 50Mω Or More (Between Power Terminal And Case) |
Setting Range |
[Slope setting] Built-in variable resistor for setting (0 to 100% of output range) or external variable resistor for setting (10 kΩ) [Output bias setting] Built-in variable resistor for setting (0 to 100% of output range) Alternatively, if there is no external variable resistor for setting (10 kΩ) and the optional heater burnout alarm is installed, the built-in variable resistor cannot be used. [Soft start time] 1 to 20 seconds |
Rated Voltage (V) |
220 |
Input Signal |
Terminal Switching Of Dc4-20Ma (Internal Resistance 100Ω), Dc1-5V (Internal Resistance 25Kω), On-Off Contact Signal, Resistance Signal (10Kω, Manual) |
Import Country |
Direct Import from Japan |
Output |
[Control method] Phase control/constant current type/frequency division control [Output range] Basic type: 0 to 98% of rated voltage, constant voltage type: 0 to 98% of rated voltage, constant current type: 0 to 100 of rated current %, Constant power type: 0 to 98% of rated voltage x 0 to 100% of rated current [Output accuracy] Basic type: Within ±10% of rated voltage, Constant voltage type: Within ±3% of rated voltage ±10% variation), constant current type: within ±3% of the rated current (when the load resistance is varied by a factor of 1 to 10), constant power type: within ±3% of the rated power (when the load resistance is varied by a factor of 1 to 3, ±10% fluctuation of rated voltage) |
Cooling Method |
Natural Cooling |
Operating Temperature Range |
-10 to +55℃ (Reduced Load Current Above 50°C) |
Name of Manufacturer/Packer/Importer |
Azbil Corporation |
Rated Frequency (Hz) |
50 / 60Hz (Automatic Switching) |
Operation Mode |
Switch By Contact Signal |
Overcurrent Protection |
Thyristor Gate Off (120% Or More Of The Rated Current, But With Built-In Ct Or Externally Attached), When The Heater Is Short-Circuited, It Is Protected With A Built-In Fast-Acting Fuse (Built-In Model Only) |
Rated Voltage Fluctuation Range |
± 10% Of Rated Voltage |
Output Contact |
2 Points, Maximum 250V Ac, 1A |
Alarm Type |
Overcurrent (with built-in or external CT): LED 2 lights, alarm contact output 1 ON Rapid fuse blown (30 A or more): LED 3 lights, alarm contact output 1 ON Heat sink overheat error (200 A or more): LED 4 lights, alarm contact output 1 ON Thyristor element Error: LED1 flashes, alarm contact output 2 ON Operation error: LED2 flashes, alarm contact output 2 ON Heater disconnection detection: LED3 flashes, alarm contact output 2 ON |
Looking for bulk pricing or different specifications?