View
View
View
View
| Model No | KRG-11 |
| Type of Product | Distance-Measuring Crane Approach Warning Device |
| Protection Class | IP40 (IEC standard) |
| Country of Origin | Japan |
Model No |
KRG-11 |
Type of Product |
Distance-Measuring Crane Approach Warning Device |
Protection Class |
IP40 (IEC standard) |
Country of Origin |
Japan |
Mass (g) |
Approximately 396 (including 1m cable and bracket) |
Connector |
Pull-out cable type 10-core cabtyre cable 1m |
Monotaro ID |
58766709 |
Shock Resistance |
490m/s2(50G) 2 hours each in X, Y, and Z directions |
Ambient Illumination to Use (Lx) |
Halogen/mercury lamp: 10,000 or less, fluorescent lamp: 6,000 or less (maximum illumination) |
Vibration Resistance |
Frequency/10 to 55Hz, double amplitude/1.5mm X, Y, Z directions 2 hours each |
Power Supply Voltage |
AC 100 to 240 V (voltage fluctuation rate within ±10%) 50/60Hz |
Case Material |
Body: ABS resin, Display: Acrylic |
Import Country |
Direct Import from Japan |
Power Consumption |
3.0VA or less (at AC100V), 6.0VA or less (at AC200V) |
Output |
Distance setting output (OUT1, 2) - Contact output (resistive load 240V AC continuous 1A) Output logic is set by DIP switch / Alarm output (OUT3) - Contact output (resistive load 240V AC continuous 1A) Normally - OPEN, when ALARM indicator light is on etc. - CLOSE / Fault output (OUT4) - Contact output (resistive load 240V AC continuous 1A) Normally - CLOSE, when light emitting or receiving circuit is abnormal - OPEN |
Response Time |
70ms or less |
Name of Manufacturer/Packer/Importer |
Hokuyo Electric Co., Ltd. |
Detection Distance (m) |
0.4 to 10 |
Indicator Lamp |
[Red] LEVEL (5 points) - Lights up according to the amount of light received / OUT1, 2 - Lights up within the respective set distances / FAULT - Lights up when there is an abnormality in the light emitting or receiving circuit / ALARM - Lights up when the LEVEL indicator light is lit within the range of 1 to 3 points / POWER - Lights up when the power is turned on |
Specifications |
●Settings: VR1...Volume for OUT1, VR2...Volume for OUT2 ●Insulation resistance/withstand voltage: 100MΩ (between power supply and contacts), AC1,500V for 1 minute (between power supply and contacts) |
Operating Temperature / Humidity Range |
-10 to +50°C, 85% RH or less (no condensation or freezing) |
Objects to Detect |
Dedicated reflector (specified item)x1 *Even outside the detection range (10m or more), it may be affected by highly reflective objects. Do not install other reflectors in the direction of the optical axis. |
Response |
200 mm |
Options |
Reflector (reflector for KRG/PD, RRP-KRG10) |
Repeatability (mm) |
±100 |