| Type of Product | Safety Light Curtain |
| Suitable For | Compliance with regulations and certifications: CE marking (machinery directive, EMC directive, RoHS directive), UKCA marking (machinery regulations, EMC regulations, RoHS regulations), TUV SUD certification, TUV SUD certification (USA and Canada), OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06, Korea KCs mark |
| Model No | SF4D-H64-01 |
| Country of Origin | Japan |
Type of Product |
Safety Light Curtain |
Suitable For |
Compliance with regulations and certifications: CE marking (machinery directive, EMC directive, RoHS directive), UKCA marking (machinery regulations, EMC regulations, RoHS regulations), TUV SUD certification, TUV SUD certification (USA and Canada), OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06, Korea KCs mark |
Model No |
SF4D-H64-01 |
Country of Origin |
Japan |
Name of Manufacturer/Packer/Importer |
Panasonic Devices SUNX Co., Ltd. |
Import Country |
Direct Import from Japan |
Monotaro ID |
70321448 |
RoHS Directive |
Correspondence |
Mass (g) |
About 3200 |
Specifications |
●Light curtain (hand type) with 20mm optical axis pitch, compatible with domestic press machines and shears. ●Effective aperture angle: ��2.5�� or less when the detection distance exceeds 3m (according to IEC 61496-2). ●PFH <sub>D</sub> /MTTF <sub>D</sub> : 3.09x10 <sup>-9</sup> /383 years |
Function |
Test input function: Equipped, Interlock function: Equipped [Manual reset/Automatic reset (switchable by wiring)] (Uses 8-core or 12-core cable), Lockout release function: Equipped, External device monitor function: Equipped (Uses 8-core or 12-core cable), App indicator function: Equipped (When using optical synchronization, only the receiver lights up), Muting function: Equipped (Uses 12-core cable), Override function: Equipped (Uses 12-core cable), Power saving function: Equipped |
Power Supply Voltage (V) |
24 DC -30 to 20%, Ripple P-P 10% or less (excluding voltage drop due to cables) |
Response Time |
Auxiliary output: OFF response: 60 ms or less, ON response: 60 ms or less Control output: OFF response: 10 ms or less (when not connected in series or parallel), 18 ms or less (when connected in series or parallel), ON response: 50 ms or less |
Current Consumption (mA) |
Emitter: 120 or less, Receiver: 150 or less |
Applicable Standard |
International Standards: IEC 61496-1/2 (Type 4), ISO 13849-1:2015 (Category 4, PLe), IEC 61508-1 to 3 (SIL3); Japan: JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508-1 to 3 (SIL3); Europe: EN ISO 13849-1:2015 (Category 4, PLe), EN55011, EN1000-6-2, EN IEC 63000; North America: ANSI/UL 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, CAN/CSA E61496-1/2; China: GB/T 4584 |
Output Operation |
(Auxiliary output) When control output is ON: OFF, when control output is OFF: ON (Control output) ON when all beams are received, OFF when one or more beams are blocked (It also turns OFF when there is an abnormality inside the safety light curtain or an abnormality in the synchronization signal). |
Control Output |
PNP open-collector transistor / NPN open-collector transistor (switchable) <When PNP output is selected> Maximum source current: 350 mA Applied voltage: Same as power supply voltage (between control output and +V) Residual voltage: 2 V or less (source current 350 mA) (excluding voltage drop due to cables) Leakage current: 0.2 mA or less (including power-off state) Maximum load capacity: 2.2 ��F Load wiring resistance: 3 �� or less <When NPN output is selected> Maximum sink current: 350 mA Applied voltage: Same as power supply voltage (between control output and 0 V) Residual voltage: 2 V or less (sink current 350 mA) (excluding voltage drop due to cables) Leakage current: 0.2 mA or less (including power-off state) Maximum load capacity: 2.2 ��F Load wiring resistance: 3 �� or less |
Detection Distance (m) |
Short mode: 0.2 to 9 / Long mode: 0.8 to 15 (switchable with DIP switch) |
Short Circuit Protection |
Equipment |
Mutual Interference Prevention |
<When not connected in series or parallel> Line synchronization: 2 units or less (automatic) Optical synchronization: 2 units or less (switchable with DIP switch) <When connected in series or parallel> Serial connection: 5 units or less (however, the total number of optical axes must be 256 or less) Parallel connection: 3 units or less (however, the total number of optical axes must be 192 or less) Mixed series and parallel connections: 5 units or less (however, the total number of optical axes must be 144 or less) |
Output |
Auxiliary output: PNP open-collector transistor/NPN open-collector transistor (switchable) <When PNP output is selected> Maximum source current: 60 mA Applied voltage: Same as power supply voltage (between auxiliary output and +V) Residual voltage: 2 V or less (source current 60 mA) (excluding voltage drop due to cables) Leakage current: 0.2 mA or less (including when power is off) <When NPN output is selected> Maximum sink current: 60 mA Applied voltage: Same as power supply voltage (between auxiliary output and 0 V) Residual voltage: 2 V or less (sink current 60 mA) (excluding voltage drop due to cables) Leakage current: 0.2 mA or less (including when power is off) |
Set Contents |
Emitter / receiver set |
Number of optical axes |
64 |
Detection Width (mm) |
1260 |
Synchronization Type |
Line synchronization/optical synchronization (switchable with DIP switch) |
Looking for bulk pricing or different specifications?