View
View
View
View
| Weight | ≈ 400 g (≈ 490 g) |
| Type of Product | Safety Door Switches |
| Model No | SFDL2-PS6C-M20K |
| Current Consumption | Supplying power: 0.26A Nor mAl: mAx. 0.2A (approx. 3 seconds after supplying power) |
Weight |
≈ 400 g (≈ 490 g) |
Type of Product |
Safety Door Switches |
Model No |
SFDL2-PS6C-M20K |
Current Consumption |
Supplying power: 0.26A Nor mAl: mAx. 0.2A (approx. 3 seconds after supplying power) |
Material |
Head: zinc or PA, case: PA |
Country of Origin |
South Korea |
Name of Manufacturer/Packer/Importer |
Teknocrats Control System (I) Pvt Ltd. |
Rated Voltage |
24 VDC, class 2 |
Operating Frequency |
Max. 20/min |
Contact Resistance |
≤ 100 mΩ |
Insulation Resistance |
≥ 100 MΩ (500 VDC Megger) |
Conditional Short Circuit Current |
100A |
Protection Structure |
IP67(IEC standerd, except head) |
Dielectric Strength Between Each Terminal and Non-Live Part |
6 kV |
Environment Ambient Temperature |
-10 to 55℃, Storage: -25 to 65℃ |
Directing Opening Force |
Min. 80N |
Vibration Malfunction |
0.35 mm single amplitude at frequency of 10 to 55Hzin each X,Y,Z direction for 10 min |
Shock Malfunction |
80m/s² (approx. 8G) in each X, Y, Z direction for 3 times |
Directing Opening Distance |
Min. 10 mm |
Shock |
1,000m/s² (approx. 100G) in each X, Y, Z direction for 3 times |
Life Cycle Mechanical |
Min. 1,000,000 operations (20/min) |
Operating Speed |
0.05 to 1m/s |
Life Cycle Electrical |
≥ 100,000 operations (250 VAC~/6 A) |
Dielectric Strength Between The Terminals Of Same Polarity |
2.5kV |
Locking Pullout Strength |
Min. 1,300N |
Rated Load Voltage & Current |
Resistive load: 6 A/250 VAC~, 0.6 A/250 VDC Inductive load (IEC): AC-15 3 A/240 VAC~, DC-13 0.27 A/250 VDC Inductive load (UL): A300, Q300 |
Dielectric Strength Between The Terminals Of Different Polarity |
4 kV |
Insulation Class |
Class E |
Environment Ambient Humidity |
35 to 85% RH, Storage: 35 to 85% RH |
Indicator |
Solenoid status or contact status (orange, depending on connection) |