Filter

Categories
Price Range
Min Price:
Max Price:
₹
-
₹
Brands
Discount
Country of Origin

3 phase accl

Showing 3 out of 3 products

Sort by
₹6,843 - ₹37,759
Elmeasure ALM300P 3 Phase Automatic Changeover with Current Limiter is a contactor-based power transfer unit designed for managing three-phase electrical supply systems. It enables automatic switching between primary and alternate three-phase power sources based on availability, ensuring controlled load transfer within commercial and industrial installations. The integrated current limiter regulates load conditions during alternate source operation, helping maintain balanced performance and protecting connected equipment from excessive current draw. Its contactor-based architecture provides dependable electrical isolation and consistent switching functionality. The ALM300P features a compact, panel-compatible design suitable for structured electrical distribution boards. It continuously monitors supply status and initiates automatic changeover without manual intervention, supporting uninterrupted operational flow in power-dependent environments. The system is engineered for stable performance under varying load conditions and is compatible with standard three-phase electrical networks. Designed for reliability and controlled energy management, the ALM300P is suitable for applications requiring automated source transfer with built-in current limiting in industrial, commercial, and institutional setups.
green checkType : Contactor Based
green checkModel No : iACCL M300
green checkPhase : 3 Phase
green checkType of Product : Automatic Changeover with Current Limiter
green checkProtection : Under/Over Voltage
green checkOperational Voltage : 180-270 V AC
₹2,123 - ₹2,595
The L&T Tripper 30A Single Phase ACCL (Automatic Changeover with Current Limiter) is a sophisticated device designed to ensure a seamless transition between main power and backup power sources while providing current limiting protection. This ACCL is ideal for residential, commercial, and small industrial applications where reliable power continuity and safety are paramount. With a current rating of 30 A and operating at single-phase, it is perfectly suited for a variety of electrical loads. One of the key features of the L&T Tripper ACCL is its automatic changeover functionality, which ensures that critical loads are transferred to a backup power source, such as a generator, without any manual intervention when the main power supply fails. This automatic switching capability minimizes downtime and maintains the continuity of essential services, making it a crucial component in power management systems. In addition to its changeover functionality, the L&T Tripper ACCL incorporates a current limiting feature that protects electrical appliances from overcurrent situations. This ensures the safety of connected devices and prevents potential damage caused by electrical surges. The device is built with high-quality components, ensuring durability and long-term reliability. It also adheres to international safety standards, providing users with peace of mind regarding its performance and safety.
green checkType of Product : Single Phase ACCL
₹6,607 - ₹6,607
Elmeasure ALM330P 3 Phase (EB) & Single Phase (DG) Automatic Changeover with Current Limiter is a contactor-based solution designed for efficient power source management between electricity board supply and diesel generator input. Engineered to support three-phase EB and single-phase DG configurations, this system ensures controlled and seamless switching based on power availability. The built-in current limiter enhances protection by regulating load during DG operation, preventing overload conditions and maintaining system stability. Its contactor-based design offers reliable electrical isolation and consistent switching performance in commercial and industrial environments. The ALM330P features a compact and panel-friendly construction, making it suitable for structured electrical installations. It is designed to monitor supply parameters and automatically transfer the connected load to the available source without manual intervention. The integration of protective components helps safeguard connected equipment from abnormal current conditions during generator usage. Built for durability and operational consistency, this automatic changeover unit is suitable for applications requiring controlled backup power management and balanced load handling across EB and DG sources.
green checkType : Contactor Based
green checkModel No : iACCL M330
green checkPhase : 3 Phase (EB) & Single Phase (DG)
green checkType of Product : Automatic Changeover with Current Limiter
green checkProtection : Under/Over Voltage
green checkOperational Voltage : 180-270 V AC
Recommended Items
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
21
Pack of 40 piece
₹110 ₹110
0.01% OFF
oos-available Ships within 24 hrs
sku-leadTime Ships within 10 days
oos-available Ships within 24 hrs
sku-leadTime Ships within 10 days
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
Browsing History
sku-leadTime Ships within 5 days
sku-leadTime Ships within 7 days
sku-leadTime Ships within 3 days
sku-leadTime Ships within 7 days
sku-leadTime Ships within 10 days