| Type of Product | Range Sensor |
| Model No | URM-40LCN-EW |
| Light Source | Semiconductor laser λ=905nm, Laser safety class 1 |
| Response Time | Output: 50 ms or less (varies depending on settings) |
Type of Product |
Range Sensor |
Model No |
URM-40LCN-EW |
Light Source |
Semiconductor laser λ=905nm, Laser safety class 1 |
Response Time |
Output: 50 ms or less (varies depending on settings) |
Monotaro ID |
58767585 |
Mass (g) |
Approximately 450 (main unit only) |
Protection Class |
IP67 |
Insulation Resistance |
10MΩ |
Input |
INPUT / 3 points: Area 1, Area 2, Area 3 / Synchronous input (maximum area: 7 patterns in total) |
Country of Origin |
Japan |
Import Country |
Direct Import from Japan |
Interface |
Ethernet 100BASE-TX (Auto-negotiation) |
Output Type |
NPN output |
Power Consumption (W) |
8.4 or less (steady state) |
Output |
OUTPUT/ 5 points: Detection 1, synchronous output, Detection 2, Detection 3, synchronous master, Ready, Fault |
Vibration Resistance |
10 to 55 Hz, double amplitude 1.5 mm, 2 hours each in X, Y, and Z directions / 55 to 200 Hz, 98 m/s² (10 G), sweep 2 minutes, 1 hour each in X, Y, and Z directions |
Repeatability |
Reflectance 90% White Kent paper / 0.1-20m: σ<10mm*1, 20-40m: σ<15mm*1 Indoor environment (fluorescent light 1,000lx or less) |
Name of Manufacturer/Packer/Importer |
Hokuyo Electric Co., Ltd. |
Case Material |
Optical window: Polycarbonate Body: Aluminum die-cast |
Power Supply Voltage |
DC 10 to 30 V |
Indicator Lamp |
Power/operation indicator (blue), area judgment indicator (orange) |
Specifications |
●Detection distance and detectable object: [Guaranteed detection value] 0.1 to 40 m*1 (white Kent paper with 90% reflectivity, 500 mmx500 mm), 0.1 to 18 m*1 (black paper with 10% reflectivity, 500 mmx500 mm) *1 Indoor environment (fluorescent light 1,000 lx or less), [Maximum detection distance] 60 m, Minimum detectable object: [Normal mode] 65 mm (5 m), 130 mm (10 m), 260 mm (20 m), [High resolution mode] 33 mm (5 m), 65 mm (10 m), 130 mm (20 m) ●Angular resolution/scanning time: 0.25°/25 ms (normal mode), 0.125°/50 ms (high resolution mode) ●Distance average accuracy: white Kent paper with 90% reflectivity / 0.1 to 30 m: ±20 mm*1, 30 to 40 m: ±30 mm*1 *1 Indoor environment (fluorescent lighting 1,000lx or less) *Current: Steady-state current 700mA or less at DC12V, startup current 1.3A (typ.) at DC12V *Please use a power supply with sufficient power capacity. |
Ambient Illumination to Use (Lx) |
100000 *Detection cannot be guaranteed when exposed to direct external light (please make sure not to expose to afternoon sun, etc.). |
Offset Angle |
Scans: 270° |
Operating Temperature / Humidity Range |
-10 to +50°C 85%RH *However, there must be no condensation or freezing. |
Startup Time |
It starts working within 15 minutes after power on. |