| Type of Product | Range Sensor |
| Model No | UST-05LA |
| Light Source | Semiconductor laser (905nm) Laser safety class 1 |
| Response Time | OFF/66msec to 3241msec, ON/66msec to 3241msec *The default setting is 66msec. The ON/OFF delay function can be switched from the application's function settings. When switching areas, there will be an additional delay of up to one scan time. |
Type of Product |
Range Sensor |
Model No |
UST-05LA |
Light Source |
Semiconductor laser (905nm) Laser safety class 1 |
Response Time |
OFF/66msec to 3241msec, ON/66msec to 3241msec *The default setting is 66msec. The ON/OFF delay function can be switched from the application's function settings. When switching areas, there will be an additional delay of up to one scan time. |
Monotaro ID |
58767601 |
Accuracy |
Distance measurement: 60 to 5000±40* *Accuracy is measured using a reference reflector (white Kent paper) under the standard environment at the time of shipment. |
Mass (g) |
130 (excluding cable) |
Protection Class |
IP65 |
Input |
6 inputs (photocoupler input, anode common, input ON current 4mA) / Inputs 1 to 5: detection area switching input, synchronous input: slave unit synchronous signal input |
Country of Origin |
Japan |
Import Country |
Direct Import from Japan |
Interface |
USB (USB micro-B type connector) |
Resolution |
0.5 degrees |
Output |
5 outputs (photocoupler/open collector output DC30V 50mA MAX.) / Output 1: Output OFF when inside area is detected, Output 2: Output OFF when inside area is detected, Output 3: Output OFF when inside area is detected, Output 4: Fault output (output ON under normal conditions), Output 5: Synchronous output (Note) When a fault output is issued, outputs 1 to 3 will indicate the presence of an obstacle. |
Name of Manufacturer/Packer/Importer |
Hokuyo Electric Co., Ltd. |
Power Supply Voltage |
DC12/DC24 (operating voltage range 10 to 30, ripple within 10%) |
Detection Distance (mm) |
60 to 5000 (white Kent paper), 60 to 2000 (at 10% reflectivity), minimum detectable object: 130 (varies depending on distance) |
Current Consumption (mA) |
150 or less (when using DC24V) However, an inrush current of approximately 400 is required at startup |
Function |
Synchronous operation mode (set by application)*, synchronous slave (0°), synchronous slave (90°), synchronous slave (180°), synchronous slave (270°) *The factory setting is synchronous master. When using the synchronization function, perform synchronous wiring and set the synchronous slave by the application. Up to two slaves can be connected to the master. |
Specifications |
Hysteresis: Hysteresis 6.25%, Hysteresis 3.125%, No Hysteresis (default setting) |
Ambient Illumination to Use (Lx) |
80000 or less Note: Direct exposure to strong light such as sunlight may result in incorrect output. |
Time |
Scanning: 25 msec (motor rotation speed 2400 rpm) |
Offset Angle |
Scans: 270° |
Operating Temperature / Humidity Range |
-10℃ to +50℃, 85% RH or less (no condensation or freezing) |
Cord |
UUST202 |
Repeatability (mm) |
σ<20* *Accuracy is measured using a standard reflector (white Kent paper) under the standard environment at the time of shipment. |