View
View
View
View
| Type of Product | Range Sensor |
| Model No | UXM-30LAH-EWA |
| Light Source | Semiconductor laser λ=905nm, Laser safety class 1 |
| Monotaro ID | 58767865 |
Type of Product |
Range Sensor |
Model No |
UXM-30LAH-EWA |
Light Source |
Semiconductor laser λ=905nm, Laser safety class 1 |
Monotaro ID |
58767865 |
Mass (g) |
Approximately 1200 (including cable) |
Protection Class |
IP67 |
Input |
INPUT / 5 points: Synchronous input, area input 1 to 4 (total 15 patterns) |
Country of Origin |
Japan |
Import Country |
Direct Import from Japan |
Interface |
Ethernet 100BASE-TX(Auto-negotiation) |
Power Consumption (W) |
7.2 or less (steady state) / When heater is used (below 0°C) DC12V: 15 or less, DC24V: 30 or less |
Resolution |
Approximately 0.125 degree (360°/2880 division) |
Output |
OUTPUT / 6 points: Synchronous master output, Synchronous output, Fault output, Detection output 1 to 3 |
Name of Manufacturer/Packer/Importer |
Hokuyo Electric Co., Ltd. |
Power Supply Voltage |
DC 10 to 30 V |
Specifications |
Distance accuracy: [Black paper with 10% reflectivity] 0.1 to 15 m: ±30 mm, 15 to 30 m: ±50 mm*1, 0.1 to 30 m: ±50 mm*2 Ambient illumination: 3,000 lx or less, 0.1 to 20 m: ±50 mm*2 Ambient illumination: 100,000 lx or less [White Kent paper with 90% reflectivity] 0.1 to 30 m: ±30 mm*1, 0.1 to 30 m: ±50 mm*2 Ambient illumination: 3,000 lx or less, 0.1 to 30 m: ±50 mm*2 Ambient illumination: 100,000 lx or less *1 Indoor environment (fluorescent light 1,000 lx or less) *2 Detection cannot be guaranteed when exposed to direct external light (please make sure that the sensor is not exposed to sunlight such as setting sun). ●Detection distance and detectable object: [Guaranteed detection value] 0.1 to 30 m* (10% reflectance black paper, 500 mmx500 mm), 0.1 to 80 m* (90% reflectance white Kent paper, 1000 mmx1500 mm) *Indoor environment (fluorescent light 1,000 lx or less) [Maximum detection distance] 80 m (maximum area setting value) [Minimum detectable object] 33 mm (5 m), 65 mm (10 m), 200 mm (30 m) ●Measurement resolution and repeatability: 1 mm unit / [10% reflectance black paper] 0.1 to 15 m: σ<10 mm, 15 to 30 m: σ<15 mm*1, 0.1 to 30 m: σ<20 mm*2 Ambient illuminance 3,000 lx or less, 0.1 to 20 m: σ<30 mm*2 Ambient illuminance 100,000 lx or less [White Kent paper with 90% reflectivity] 0.1 to 30m: σ<10mm*1, 0.1 to 30m: σ<15mm*2 Ambient illuminance 3,000lx or less, 0.1 to 30m: σ<30mm*2 Ambient illuminance 100,000lx or less *1 Indoor environment (fluorescent light 1,000lx or less), *2 Detection cannot be guaranteed in direct external light (please make sure not to let in sunlight such as afternoon sun). ● Current: [Steady state current] 600mA or less at 12VDC, 300mA or less at 24VDC [Start-up current] 1.5A or less at 12VDC, 0.75A or less at 24VDC / When heater is used (below 0°C): 1.25A or less at 12VDC, 1.25A or less at 24VDC |
Time |
Scanning: 50ms (motor rotation speed 1200rpm) |
Offset Angle |
Scans: 190° |
Operating Temperature / Humidity Range |
-10 to +50°C, 85% RH (-30 to +50°C, 85% RH when heater is in use), but no condensation or freezing |