View
View
View
View
| Type of Product | Range Sensor |
| Model No | UTM-30LX-EW |
| Material | Optical surface: Polycarbonate |
| Light Source | Semiconductor laser λ = 905nm FDA laser safety class 1 |
Type of Product |
Range Sensor |
Model No |
UTM-30LX-EW |
Material |
Optical surface: Polycarbonate |
Light Source |
Semiconductor laser λ = 905nm FDA laser safety class 1 |
Monotaro ID |
58767847 |
Accuracy |
Distance measurement: 0.1 to 10m/±30, 10 to 30m/±50 (white Kent paper) *2 [Ambient illuminance 3000lx or less] White Kent paper 0.1 to 10m/±30*1 [Ambient illuminance 100000lx or less] White Kent paper 0.1 to 10m/±50*1 *1 Detection cannot be guaranteed when exposed to direct external light (please take care to avoid exposure to afternoon sun, etc.) *2 Indoor environment (fluorescent light 1000lx or less) |
Mass (g) |
300 (including cable) |
Protection Class |
IP67 (IEC standard)* * The end of the Ethernet cable (connector) does not have an IP67 protective structure. |
Country of Origin |
Japan |
Import Country |
Direct Import from Japan |
Interface |
Ethernet 100BASE-TX(Auto-negotiation) |
Resolution |
Approximately 0.25 degrees (360°/1440 divisions) |
Storage Temperature |
-25 to 75℃ |
Output |
Synchronous output (NPN open collector DC30V, 30mA or less) |
Vibration Resistance |
10 to 55Hz double amplitude 1.5mm XYZ directions 2 hours each, 55Hz to 200Hz 49m/s2 sweep 2 minutes X, Y, Z directions 1 hour each |
Name of Manufacturer/Packer/Importer |
Hokuyo Electric Co., Ltd. |
Power Supply Voltage |
DC 12 V ±10% |
Current Consumption (mA) |
700 or less, but approximately 1A at startup |
Indicator Lamp |
[Power indicator (green)] Lights up when power is on. [Indicator (orange)] Lights up when operating normally, flashes when there is a malfunction. |
Specifications |
Detection distance and detection object: [Guaranteed detection value] 0.1 to 30 m (white Kent paper) * * Indoor environment (fluorescent light 1000 lx or less) [Maximum detection distance] 60 m (output limit value) [Minimum detectable object] 130 mm (10 m) ● Distance measurement resolution and repeatability: 1 mm unit / 0.1 to 10 m: σ<10 mm, 10 to 30 m: σ<30 mm (white Kent paper) * [Ambient illuminance 3000 lx or less] σ<10 mm (white Kent paper up to 10 m) [Ambient illuminance 100,000 lx or less] σ<30 mm (white Kent paper up to 10 m) * Indoor environment (fluorescent light 1000 lx or less) |
Insulation Resistance (MOhm) |
10DC500V Megger |
Time |
Scanning: 25ms/scan* * When using measurement commands other than MD, MS, and ME, the response speed may be slower depending on the surrounding environment. |
Offset Angle |
Scans: 270° |
Operating Temperature / Humidity Range |
-10℃ to +50℃, 85% RH or less (However, there must be no condensation or freezing) |
Cord |
UUTM013 |
EMC Standard to Conform |
(EMI)EN61326-1:2013, EN55011:2009 + A1:2010 (EMS) EN61326-1:2013, EN61000-4-2:2009, EN61000-4-3:2006 + A1:2008 + A2:2010, EN61000-4-4:2012, EN61000-4-6:2009, EN61000-4-8:2010 |