| Type of Product | Range Sensor |
| Model No | UXM-30LXH-EHA |
| Light Source | Semiconductor laser λ=905nm, FDA laser safety class 1 |
| Monotaro ID | 58767926 |
Type of Product |
Range Sensor |
Model No |
UXM-30LXH-EHA |
Light Source |
Semiconductor laser λ=905nm, FDA laser safety class 1 |
Monotaro ID |
58767926 |
Mass (g) |
Approximately 1200 (including cable) |
Protection Class |
IP67 |
Input |
INPUT / 1 point: Synchronous input |
Country of Origin |
Japan |
Import Country |
Direct Import from Japan |
Interface |
Ethernet 100BASE-TX(Auto-negotiation) |
Power Consumption (W) |
7.2 or less (steady state) / When heater is used (below 0°C) DC12V: 15 or less, DC24V: 30 or less |
Shock Resistance |
196m/s2 10 times each in X, Y, and Z directions |
Resolution |
Approximately 0.125 degree (360°/2880 division) |
Output |
OUTPUT / 3 points: Synchronous master output, synchronized output, fault output |
Vibration Resistance |
10 to 55Hz double amplitude 1.5mm X, Y, Z directions 2 hours each, 55 to 200Hz 19.6m/s2 sweep 2 minutes X, Y, Z directions 1 hour each |
Repeatability |
[Black paper with 10% reflectivity] 0.1 to 15 m: σ<10 mm, 15 to 30 m: σ<15 mm*1, 0.1 to 30 m: σ<20 mm*2 Ambient illumination: 3,000 lx or less, 0.1 to 20 m: σ<30 mm*2 Ambient illumination: 100,000 lx or less [White Kent paper with 90% reflectivity] 0.1 to 30 m: σ<10 mm*1, 0.1 to 30 m: σ<15 mm*2 Ambient illumination: 3,000 lx or less, 0.1 to 20 m: σ<30 mm*2 Ambient illumination: 100,000 lx or less *1 Indoor environment (fluorescent light 1,000 lx or less), *2 Detection cannot be guaranteed when exposed to direct external light (please make sure that the sensor is not exposed to sunlight such as afternoon sun). |
Name of Manufacturer/Packer/Importer |
Hokuyo Electric Co., Ltd. |
Power Supply Voltage |
DC 10 to 30 V |
Indicator Lamp |
Power/operation indicator (green), communication measurement indicator (orange) |
Specifications |
Distance average accuracy: [Black paper with 10% reflectivity] 0.1 to 15 m: ±30 mm, 15 to 30 m: ±50 mm*1, 0.1 to 30 m: ±50 mm*2 Ambient illuminance 3,000 lx or less, 0.1 to 20 m: ±50 mm*2 Ambient illuminance 100,000 lx or less [White Kent paper with 90% reflectivity] 0.1 to 30 m: ±30 mm*1, 0.1 to 30 m: ±50 mm*2 Ambient illuminance 3,000 lx or less, 0.1 to 30 m: ±50 mm*2 Ambient illuminance 100,000 lx or less *1. Indoor environment (fluorescent light 1,000 lx or less) *2. Detection cannot be guaranteed when exposed to direct external light (please make sure that the sensor is not exposed to sunlight such as setting sun). Detection distance and detection object: [Guaranteed detection value] 0.1 to 30 m* (10% reflectivity black paper, 500 mmx500 mm), 0.1 to 80 m* (90% reflectivity white Kent paper, 1000 mmx1500 mm) *Indoor environment (fluorescent light 1,000 lx or less) [Maximum detection distance] 120 m (output limit value) [Minimum detectable object] 33 mm (5 m), 65 mm (10 m), 200 mm (30 m) ●Current: [Steady state current] 600 mA or less at 12 VDC, 300 mA or less at 24 VDC [Start-up current] 1.5 A or less at 12 VDC, 0.75 A or less at 24 VDC / When heater is used (below 0°C): 1.25 A or less at 12 VDC, 1.25 A or less at 24 VDC |
Time |
Scanning: 50ms (motor rotation speed 1200rpm) |
Offset Angle |
Scans: 190° |
Operating Temperature / Humidity Range |
-10 to +50°C 85%RH, -30 to +50°C 85%RH (when heater is in use) *However, there must be no condensation or freezing. |
Weatherability |
The detection distance will be shorter due to rain, snow, or sunlight.* *Please check the environmental effects on the actual device. |
Startup Time |
Operates within 30 seconds of power-on |
Measurement Resolution |