View
View
View
View
| Type of Product | Power Supply |
| Model No | QT20.481 |
| Power Factor | 0.94 |
| Rated Output Voltage (V) | 48 DC |
Type of Product |
Power Supply |
Model No |
QT20.481 |
Power Factor |
0.94 |
Rated Output Voltage (V) |
48 DC |
Monotaro ID |
48408868 |
Mass (g) |
870 |
Type |
Mode switching |
Inrush current (A) |
(Input)3 |
Range |
size |
Output Current Range |
10 to 8.7 Amp |
Output Voltage (V) |
48 to 55 DC |
Output Current (A) |
8.7/55 V, 10/48 V |
Efficiency (%) |
95.4%(typ.) |
Country of Origin |
Japan |
Import Country |
Direct Import from Japan |
Name of Manufacturer/Packer/Importer |
PULS |
Input Voltage (V) |
AC 380 to 480 |
Specifications |
Dimension Q Series. PULS' Q series DIN rail power supplies combine compact size with high efficiency thanks to their advanced detailed design and synchronous rectification. This, along with a 150% short-term maximum peak power capability and large integrated output capacitors, facilitates motor starting, capacitor charging, and reverse energy absorption, often allowing the use of lower power class equipment. Excellent immunity to transients and power surges, combined with low electromagnetic emissions, allows these PSUs to be used in almost any environment. Installation and use are simplified thanks to the integrated output power manager, wide-range input voltage design, and virtually zero input inrush current. Power supply diagnostics are easy with the Q series thanks to the dry DC OK contact, green DC OK LED, and red overload LED. Unique quick-connect spring clamp terminals ensure safe and fast installation, while numerous international approvals for a wide range of applications make them ideal for almost any situation. . Single-phase or three-phase installation, 80 to 960 W Active power factor correction Minimum inrush current 50% power reserve for 4 seconds (typical), controlled by intelligent power manager Quick connect spring clamp terminals LED for DC OK and overload DC OK relay contact DC input, 88 to 375 V, for single phase Active filtering of input transients Minimum 60 V ac, maximum 300 V ac (short-term operation) For parallel and serial use ● Harmonic suppression: active ● Input inrush current limiting: active ● External input fuse recommendation: B-6A/C-3A ● Derating: 12 W/°C for > +60°C ● Power reserve: 50% BonusPower ● DC-OK signal: yes ● Nominal current per input: - |
Ripple Noise (mVp-p) |
Up to 100 |
Rated/Max Power Output (VA) |
480 |
Connecting Terminal |
Spring Clamp Terminals |
Dimension (WxDxH) |
65x124x127 mm |
Type of Terminal Fitting |
DIN rail |
Looking for bulk pricing or different specifications?