| Voltage Range | Channels 1-3: Voltage measurement 600.00 V rms, transient measurement 6.0000 kV peak; Channel 4: 600.00 V rms or DC, transient measurement 6.0000 kV peak |
| Basic Accuracy | Voltage: ±0.1% of nominal voltage, Current: ±0.1%rdg. ±0.1%fs + current sensor accuracy, Active power: ±0.2%rdg. ±0.1%fs + current sensor accuracy |
| Measurement Functions | 1. Transient voltage: 2MHz sampling, 2. Frequency 1 wave: Calculated from 1 waveform, 200kHz sampling, 3. Voltage 1/2 RMS value: Calculated for each waveform with half-wave shift, Current 1/2 RMS value: Calculated for each half-wave, 4. Swell, dip, momentary power interruption: Detected using voltage 1/2 RMS value, 5. Inrush current: Detected using current 1/2 RMS value, 6. Voltage waveform comparison: Automatically generates a judgment area and compares, 7. Instantaneous flicker value: According to IEC61000-4-15, 8. Frequency 200ms: Calculated from 10 waves and 12 waves, 40-70Hz, 9. Frequency 10 seconds: Calculated from waveform over 10 seconds, 40-70Hz, 10 11. Voltage waveform peak, current waveform peak, Voltage, current, active power, apparent power, reactive power, active energy, reactive energy, power factor, displacement power factor, voltage unbalance rate, current unbalance rate, efficiency, 12. Higher-order harmonics (voltage/current): 2kHz to 80kHz bandwidth, 13. Harmonic/phase angle (voltage/current), harmonic power: 0th to 50th order, 14. Harmonic voltage-current phase difference: 1st to 50th order, 15. Total harmonic distortion rate (voltage/current), 16. Interharmonics (voltage/current): 0.5th to 49.5th order, 17. K-factor (multiplier), 18. ΔV10 flicker, IEC flicker (short-term/long-term) |
| Current Range | AC+500.00+mA to 5.0000+kA+ (measurement range varies depending on the sensor used) |
Voltage Range |
Channels 1-3: Voltage measurement 600.00 V rms, transient measurement 6.0000 kV peak; Channel 4: 600.00 V rms or DC, transient measurement 6.0000 kV peak |
Basic Accuracy |
Voltage: ±0.1% of nominal voltage, Current: ±0.1%rdg. ±0.1%fs + current sensor accuracy, Active power: ±0.2%rdg. ±0.1%fs + current sensor accuracy |
Measurement Functions |
1. Transient voltage: 2MHz sampling, 2. Frequency 1 wave: Calculated from 1 waveform, 200kHz sampling, 3. Voltage 1/2 RMS value: Calculated for each waveform with half-wave shift, Current 1/2 RMS value: Calculated for each half-wave, 4. Swell, dip, momentary power interruption: Detected using voltage 1/2 RMS value, 5. Inrush current: Detected using current 1/2 RMS value, 6. Voltage waveform comparison: Automatically generates a judgment area and compares, 7. Instantaneous flicker value: According to IEC61000-4-15, 8. Frequency 200ms: Calculated from 10 waves and 12 waves, 40-70Hz, 9. Frequency 10 seconds: Calculated from waveform over 10 seconds, 40-70Hz, 10 11. Voltage waveform peak, current waveform peak, Voltage, current, active power, apparent power, reactive power, active energy, reactive energy, power factor, displacement power factor, voltage unbalance rate, current unbalance rate, efficiency, 12. Higher-order harmonics (voltage/current): 2kHz to 80kHz bandwidth, 13. Harmonic/phase angle (voltage/current), harmonic power: 0th to 50th order, 14. Harmonic voltage-current phase difference: 1st to 50th order, 15. Total harmonic distortion rate (voltage/current), 16. Interharmonics (voltage/current): 0.5th to 49.5th order, 17. K-factor (multiplier), 18. ΔV10 flicker, IEC flicker (short-term/long-term) |
Current Range |
AC+500.00+mA to 5.0000+kA+ (measurement range varies depending on the sensor used) |
Power Range |
300.00 W to 3.0000 MW (automatically determined by the voltage and current range used) |
Power Supply |
AC adapter Z1002 (100-240V, rated 1.7 A, 50/60 Hz), battery pack Z1003 (continuous use time 180 minutes, charged via AC adapter, charging time 5 hours 30 minutes) |
Display |
6.5-inch TFT color LCD+ (640 x 480 dots) |
Type of Product |
Power Storage Analyzer |
Interface |
SD/SDHC memory card, LAN+ (HTTP server function/FTP function), USB+2.0+ (communication) |
Model No |
PQ3198 |
Country of Origin |
Japan |
Included Components |
Instruction manual x 1, Measurement guide x 1, Voltage cord L1000 x 1 (red, yellow, blue, gray, black x 4, alligator clips x 8), Spiral tube x 20, Color clips, AC adapter Z1002 x 1, Strap x 1, USB cable (1m) x 1, Battery pack Z1003 x 1, SD memory card 2GB Z4001 x 1 |
Monotaro ID |
52596104 |
Name of Manufacturer/Packer/Importer |
HIOKI E.E. CORPORATION |
Import Country |
Direct Import from Japan |
Dimension (WxDxH) |
300x211x68 mm |
Mass (Kg) |
2.6 (including battery pack Z1003) |
Measuring Time |
In addition to single-phase 2-wire/single-phase 3-wire/three-phase 3-wire/three-phase 4-wire systems, voltage/current/power measurement (DC or AC) is available via channel 4. |
Mass (g) |
2600 (when battery pack Z1003 is installed) |
Set Contents |
Main unit only (current sensor sold separately) |
Recording |
Maximum/Repeat ON: 1 year, Maximum recorded events: 9999 x 366 days (up to 9999 per day), Repeat OFF: 35 days, Maximum recorded events: 9999 |
Width (mm) |
300 |
Height (mm) |
211 |
Length (mm) |
68 |