View
View
View
View
| Model No | HTL-2401R-E1S01 |
| Resolution | Analog output/output: 16bit (50000 or more) |
| Display | Numerical display / 5 digits: 7-segment LED character height 9mm, red LED, display range / -19999 to 99999, over display / OL, zero display / leading zero suppression, display update time / 0.3 seconds (can be set in the range of 0.1 to 9.9 seconds), display accuracy / 20 ppm ± 1 digit at 23°C |
| Type of Product | Digital Panel Meter |
Model No |
HTL-2401R-E1S01 |
Resolution |
Analog output/output: 16bit (50000 or more) |
Display |
Numerical display / 5 digits: 7-segment LED character height 9mm, red LED, display range / -19999 to 99999, over display / OL, zero display / leading zero suppression, display update time / 0.3 seconds (can be set in the range of 0.1 to 9.9 seconds), display accuracy / 20 ppm ± 1 digit at 23°C |
Type of Product |
Digital Panel Meter |
Country of Origin |
Japan |
Monotaro ID |
66272057 |
Import Country |
Direct Import from Japan |
Input Signal |
Temperature measurement |
Measurement Range |
-200℃ to 850℃ ±0.2% of FS |
Load Resistance |
Analog output: Voltage output -4.7 KΩ or more, current output -300Ω or less |
Name of Manufacturer/Packer/Importer |
COCO RESEARCH |
Input Power |
DC 12-30 V |
Specifications |
●CAN communication mechanism, setting items, output update time: Write/read setting values/continuous output of measured values, CAN transmission ID, CAN reception ID, 1 ms to 9999 ms, settable in 1 ms increments ●CAN communication specifications: CAN2.0B 10 k / 20 k / 50 k / 100 k / 250 k / 500 k / 1 Mbps format (INTEL/MOTOROLA), frame (11 bit/29 bit) ●Isolation: Power supply/RTD input/other inputs/outputs ●Analog: 0-10 V ●Analog output/D/A conversion method: DAC conversion method ●Analog output/output scaling: Full scale and zero scale settings allow for arbitrary scaling ●Analog output/output update time/output response time: 1 ms to 9999 ms, settable in 1 ms increments, 0-90% response time less than 1 ms ●Analog output/output accuracy/temperature fluctuation: Voltage output to ±0.1% of full scale at 23°C, current output to ±0.1% of full scale FS@23℃ / ±200ppm/℃ or less ●Digital: CAN ●Calculation unit/moving average number: 1999/01/01 ●Update time (m): 40 ●Setting value storage: Non-volatile memory (EEPROM) ●Resistance value check function: 0 to 400Ω |
Power Consumption (W) |
3 or less |
Operating Temperature / Humidity Range |
-10℃ to +50℃ 35 to 85%RH (non-condensing) |
Tip Shape |
Input response action: None or 1 point (depending on model) [D2] Option adds 2 points |
Output update time |
1ms - 9999ms Can be set in 1ms increments |
Comparator |
None |
Communication Function |
USB: Reading and writing of setting values / continuous output of measured values |
USB |
Communication specifications: USB 2.0 (USB virtual COM serial port communication 230.4 kbps) |
Number of Input Points |
1 point resistance thermometer Pt100 (3-wire) |
3 options, 3 price levels
Volume discounts
Price locked 30 days