Fluke T+PRO Voltage and Continuity Tester :
Safer than traditional solenoid testers.
3 forms of AC/DC voltage detection: lights, beeper, vibration for added user protection and convenience.
Still indicates live voltage without battery power for added user protection.
Extra-heavy-duty, replaceable test leads for added durability.
CAT IV 600V, CAT III 1000V rated for added user protection.
Continuity beeper, GFCI Trip, Flashlight.
Backlit LCD display for easier viewing.
Resistance, Rotary Field Indication and Display Hold.
Replaceable test probes for added convenience.
Probe storage on back for added convenience.
Probe holder for easier testing.
Hazardous voltage warning light for added user protection.
Test lead strap included for better test lead management.
AC/DC Voltage: 12 V-600 V on LED bar, 10.2 V-600 V on LCD.
LCD Resolution: 0.1 V for voltages = 50 V off to save battery power.
Single point offset laser sighting.
Best accuracy in its class: + 1% of reading.
Holds temperature readings for 7 seconds.
Dual displays shows current and MAX measurements simultaneously.
Backlit display for poorly lit areas.
Comfortable ergonomic handle with protective rubber boot for added durability.
Fitted carrying case.
Robust, award winning design.
Wide temperature range from -30 to 500C (20 to 932F).
Fluke 1AC-II VoltAlert Non-Contact Voltage Detector :
Voltbeat technology and continuous self-test so you always know its working.
Upon detection, tip glows and beeper sounds.
CAT IV 1000 V for added protection.
Expanded range: 90 V to 1000 V AC or 200 V to 1000 V AC depending on model.
20 V to 90 V AC control circuit model also available.
.tg {border-collapse:collapse;border-spacing:0;}
.tg td{font-family:Arial, sans-serif;font-size:14px;padding:10px 5px;border-style:solid;border-width:1px;overflow:hidden;word-break:normal;}
.tg th{font-family:Arial, sans-serif;font-size:14px;font-weight:normal;padding:10px 5px;border-style:solid;border-width:1px;overflow:hidden;word-break:normal;}
.tg .tg-e3zv{font-weight:bold}
.tg .tg-hgcj{font-weight:bold;text-align:center}
.tg .tg-9hbo{font-weight:bold;vertical-align:top}
.tg .tg-yw4l{vertical-align:top}
Fluke T+Pro Specifications
Temperature
Operating: -10 C to 55 C (14 F to 131 F)
Storage: -30 C to 60 C (- 22 F to 140 F)
Relative humidity
0 C to 30 C (3 F to 86 F): 90 %
30 C to 40 C (86 F to 104 F): 75 %
40 C to 50 C (104 F to 1 F): 45 %
Altitude
Operating: 2,000 m (approx. 6,561.6 ft
Storage: 10,000 m (approx. 3 ,808.4 ft)
Battery type/life
AAA (2); 40 hours
Shock, vibration
Sinusoidal vibration per MIL-PRF- 8800F for a Class instrument
Safety
ISA-8 .0 .01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C . No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/
600 V CAT IV Compliance to NFPA 70E1
AC Bandwidth
45 Hz to 66 Hz
Maximum working voltage
1000 V AC/DC
Maximum measurable voltage
600 V AC/DC
Duty cycle
Indefinitely for voltages up to 240 V.
For voltages between 40 V and 600 V the duty cycle is 30 s on / 300 s off.
For voltages above 40 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s.
Voltage hazard LED
LEDs turn on at voltages > 30 V ac/dc + 35 %
LED voltage indication levels
1 V, 4 V, 48 V, 1 0 V, 08 V, 40 V, 77 V, 480 V, 600 V
LED voltage indication levels for Canadian version
1 V, 4 V, 48 V, 1 0 V, 08 V, 40 V, 347 V, 480 V, 600 V
LEDs
LEDs turn on between 70 % and 85 % of the indicated voltage on the LED, except for the 1 V LED which turns on between 50 % and 100 %.
Accuracy
AC voltage: + (3 % rdg + digits)
DC voltage: + (2 % rdg + digits)
Resistance: + (5 % rdg + 3 digits)
LCD Resolution
0.1 V for voltages < 50 V, 1 V for voltages > 50 V 0.01 k for resistance measurement
GFCI Test current
100 V - 00 V at 0 mA - 35 mA for 1 s
Standard input test current
< 5 mA
Size (H x W x L)
1.3 in x .15 in x 7.6 in (3.3 cm x 5.46 cm x 19.3 cm )
Weight
9.9 oz (0.28 kg)
.tg {border-collapse:collapse;border-spacing:0;}
.tg td{font-family:Arial, sans-serif;font-size:14px;padding:10px 5px;border-style:solid;border-width:1px;overflow:hidden;word-break:normal;}
.tg th{font-family:Arial, sans-serif;font-size:14px;font-weight:normal;padding:10px 5px;border-style:solid;border-width:1px;overflow:hidden;word-break:normal;}
.tg .tg-amwm{font-weight:bold;text-align:center;vertical-align:top}
.tg .tg-9hbo{font-weight:bold;vertical-align:top}
.tg .tg-yw4l{vertical-align:top}
Fluke 1AC VoltAlert Specifications
Operating principle
Senses the steady state electrostatic produced by ac voltage through insulation without requiring contact to the bare conductor.
A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage.
Voltage sensing ranges
Nominally, 90 V AC to 1000 V AC or 200 V AC to 1000 V AC depending on model, 45 Hz to 405 Hz; also a 20 V to 90 V control
circuit model
Detector tip style
Blade or round, depending on model
Light source
One high intensity red LED
Agency Approvals
c CSA us, CE, TUV, C-Tick
Safety Rating
1000 V, CAT IV
IP Rating
IP 40
Operating temperature
-10 C to 50 C
Operating humidity ranges
0 % to 95 % (0 C to 30 C)
0 % to 75 % (30 C to 40 C)
0 % to 45 % (40 C to 55 C)
Operating Altitude
3000 meters
Batteries
2 AAA alkaline batteries included