View
View
View
View
| Type of Product | Clamp-On Power Logger |
| Model No | PW3360-10 |
| Country of Origin | Japan |
| Name of Manufacturer/Packer/Importer | HIOKI E.E. CORPORATION |
Type of Product |
Clamp-On Power Logger |
Model No |
PW3360-10 |
Country of Origin |
Japan |
Name of Manufacturer/Packer/Importer |
HIOKI E.E. CORPORATION |
Import Country |
Direct Import from Japan |
Monotaro ID |
60935402 |
Mass (g) |
550 (without battery set PW9002 installed), 830 (with battery set PW9002 installed) |
Included Components |
Voltage cord L9438-53 x 1 (black, red, yellow, blue), AC adapter Z1006 x 1, USB cable (0.9m) x 1, instruction manual x 1, measurement guide x 1, color clips (2 each of red, yellow, blue, and white, for clamp sensor color differentiation) x 1 set, spiral tubes x 5 (for bundling clamp sensor cords) |
RoHS Directive |
Correspondence |
Specifications |
[Saved Items] Measurement Value Saved: Average value only, Average, Maximum, Minimum values / [PW3360-11]: Harmonic Data Saved: Binary format (Average value only, Average, Maximum, Minimum values) / Screen Copy: BMP format (Can be saved at minimum intervals of 5 minutes) / Waveform Saved: Binary format (Can be saved at minimum intervals of 1 minute) |
Power Supply |
AC adapter Z1006 (100V-240V, 50/60Hz), 40VA (including AC adapter) / Battery pack 9459: (DC72V, 3VA, 6 hours 10 minutes charging time with AC adapter connected), continuous use time 6 hours (backlight OFF) |
Dimension (WxDxH) |
180 x 100 x 48 mm (without battery set PW9002 installed), 180 x 100 x 67.2 mm (with battery set PW9002 installed) |
Voltage Range |
AC 600 V (Effective measurement range: 90-780 V) |
Basic Accuracy |
Voltage: ±0.3%rdg ±0.1%fs / Current: ±0.3%rdg ±0.1%fs + current sensor accuracy / Power: ±0.3%rdg ±0.1%fs + current sensor accuracy (power factor = 1) |
Startup Time (ms) |
Software: Approximately 3 sec |
Interface |
[SD/SDHC Memory Card] LAN 100BASE-TX: HTTP server function, FTP client function (measurement file acquisition by SF4102) / USB20: When connected to a PC, the SD memory card and internal memory are recognized as removable disks, and settings and data download are performed using communication software / Pulse output: When measuring cumulative power consumption, a pulse signal proportional to the active power consumption is output, open collector isolated output. |
Measuring Unit |
Voltage RMS value, current RMS value, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power (with lagging/leading indication), apparent power, power factor (with lagging/leading indication) or displacement power factor (with lagging/leading indication), active energy (consumption/regeneration), reactive energy (lagging/leading), electricity rate display, active power demand (consumption/regeneration), reactive power demand (lagging/leading), active power demand value (consumption/regeneration), reactive power demand value (lagging/leading), power factor demand, pulse input, [PW |
Function |
Connection check, setting navigation, screen copy, clock, display hold, etc. |
Current Range |
AC500mA to 5kA (measurement range varies depending on the sensor used), AC50mA to 5A (leakage current only) |
Software Version |
5.22 |
Interval (mm) |
(Save) 1 to 30 seconds, 1 to 60 minutes, 14 switching |
Display Update Rate |
Approximately 0.5 seconds (excluding when accessing SD card/internal memory, LAN/USB communication) |
Recording Media |
Real-time storage to SD memory card / internal memory |
Measuring Time |
[Number of measurable circuits] 50/60Hz, single-phase 2-wire (1 circuit/2 circuits/3 circuits), single-phase 3-wire (1 circuit), three-phase 3-wire/three-phase 4-wire (1 circuit), current only 1-3 channels |
Power Range |
300W to 9MW (depending on the voltage/current range and measurement line combination) |
Looking for bulk pricing or different specifications?