| Type of Product | Wireless Voltage and Temperature Logger |
| Power Supply | AC adapter Z2003 (AC 100-240V, 50Hz/60Hz), 2 x AA alkaline batteries (LR6), external power supply DC 5V-135V (can be supplied via USB bus power, conversion cable required) |
| No. of Channels | 2 channels (Voltage and thermocouple settings can be configured for each channel, with isolation between channels) |
| Input terminals | M3 screw terminal block |
Type of Product |
Wireless Voltage and Temperature Logger |
Power Supply |
AC adapter Z2003 (AC 100-240V, 50Hz/60Hz), 2 x AA alkaline batteries (LR6), external power supply DC 5V-135V (can be supplied via USB bus power, conversion cable required) |
No. of Channels |
2 channels (Voltage and thermocouple settings can be configured for each channel, with isolation between channels) |
Input terminals |
M3 screw terminal block |
Model No |
LR8515 |
Monotaro ID |
50973484 |
Interface |
Bluetooth |
Recording Interval |
0.1 seconds to 30 seconds, 1 minute to 60 minutes, 16 switching |
Included Components |
Measurement guide x 1, Precautions for radio wave usage x 1, AA alkaline batteries (LR6) x 2 |
Country of Origin |
Japan |
Name of Manufacturer/Packer/Importer |
HIOKI E.E. CORPORATION |
Import Country |
Direct Import from Japan |
Mass (g) |
126 (without batteries) |
Dimension (WxDxH) |
85x75x38 mm |
RoHS Directive |
Correspondence |
Compatible Models |
[Standalone Use (Manual Data Collection)] Windows PC or Windows tablet (software CD-R included) / Android smartphone or Android tablet (software free download from Google Play) *Communication range depends on the performance of the PC or tablet (approximately 30 m line of sight) / [Use as a Unit (Real-time Measurement)] Use as a unit for LR8410 or LR8416 to record and display data in real time, control up to 7 units, communication range: 30 m line of sight |
Recording mode |
Instantaneous value recording |
Display Items |
Measured value, date, time, number of recorded data, maximum value, minimum value, average value, etc. |
Measurement Range |
[Voltage] ± 50 mV to ± 50 V, maximum resolution 0.01 mV, [thermocouple] -200 ° C to 999.9 ° C, thermocouple (K, T), maximum resolution 0.1 ° C |
Function |
Alarm, scaling, recording operation retention, erroneous operation prevention, comment memory, power saving, authentication, free run |
Continuous Operating Time |
Approximately 2.5 months (1 minute recording interval, Bluetooth(R) OFF), approximately 7 days (1 second recording interval, Bluetooth(R) ON), approximately 2 days (0.1 second recording interval, real-time measurement with LR8410 or LR8416) [(using AA alkaline batteries) (reference value at 23℃)] |
Measurement accuracy |
[Voltage] ±0.05mV (50mV range), [Thermocouple] ±0.8℃ (Thermocouple K-100℃ to 999.9℃) *Reference junction compensation: Switchable between internal and external (when measuring thermocouple) *Reference junction compensation accuracy: ±0.5℃ (When internal, added to thermocouple measurement accuracy) *Temperature characteristics: (Measurement accuracy × 0.1)/℃ is added to measurement accuracy |
Maximum Input Voltage |
DC ±50V, maximum inter-channel voltage DC 60V |
Target of Measurement |
Temperature measurement using voltage and thermocouples (K, T) |
Storage Capacity |
500,000 data per channel |