Filter

Categories
Price Range
Min Price:
Max Price:
-
Discount
Type of Product
Voltage

Elmex Solar Surge Protection Device

Showing 4 out of 4 products

Sort by
₹1,025  
AC Surge Protection Device (SPD) is designed to limit transient over voltages of atmospheric origin and divert current waves to earth, so as to limit the amplitude of this over voltage to a value that is not hazardous for the electrical installation and electric switchgear. AC SPDs are designed to protect against transient over voltages caused by lightning strikes on overhead lines, switching operations, and other disturbances. Type 2 SPD: The Type 2 SPD is the main protection system for all low voltage electrical installations. Installed in each electrical switchboard, it prevents the spread of over voltages in the electrical installations and protects the load. Nominal Voltage (Un): The nominal voltage stands for the nominal voltage of the system to be protected Maximum Continuous Operating Voltage (Uc): The maximum continuous operating voltage is the r.m.s value of the maximum voltage which may be connected to corresponding terminals of the Surge Protective Device during operations. The maximum continuous operating voltage for Photovoltaic (PC) system is the value of the maximum DC voltage which may be permanently applied to terminals of SPD. The voltage protection level is the maximum instantaneous value of the voltage at terminals of SPD. The nominal discharge current is the peak value of the current that can be passed through SPD having a wave shape of 8/20 µs. The maximum discharge current is the peak value of the current which the device can safely discharge through the SPD having a wave shape of 8/20 µs. Applications Photovoltaic & Wind Industry & Automation Commercial & Residential Installations Telecom, IT & Data Centers
₹2,005  
DC Surge Protection Device (SPD) is designed to limit transient over voltages of atmospheric origin and divert current waves to earth, so as to limit the amplitude of this over voltage to a value that is not hazardous for the electrical installation and electric switchgear. Type 2 SPD: The Type 2 SPD is the main protection system for all low voltage electrical installations. Installed in each electrical switchboard, it prevents the spread of over voltages in the electrical installations and protects the load. Nominal Voltage (Un): The nominal voltage stands for the nominal voltage of the system to be protected Maximum Continuous Operating Voltage (Uc): The maximum continuous operating voltage is the r.m.s value of the maximum voltage which may be connected to corresponding terminals of the Surge Protective Device during operations. Maximum Continuous Operating Voltage for PV System (Ucpv): The maximum continuous operating voltage for Photovoltaic (PC) system is the value of the maximum DC voltage which may be permanently applied to terminals of SPD. Voltage Protection Level (Up): The Voltage Protection Level is the maximum instantaneous value of the voltage at terminals of SPD. Nominal Discharge Current (In): The nominal discharge current is the peak value of the current that can be passed through SPD having a wave shape of 8/20 µs. Maximum Discharge Current (Imax): The maximum discharge current is the peak value of the current which the device can safely discharge through the SPD having a wave shape of 8/20 µs Applications Photovoltaic & Wind Industry & Automation Commercial & Residential Installations Telecom, IT & Data Centers
₹1,061  
DC Surge Protection Device (SPD) is designed to limit transient over voltages of atmospheric origin and divert current waves to earth, so as to limit the amplitude of this over voltage to a value that is not hazardous for the electrical installation and electric switchgear. Type 1 SPD: The Type 1 SPD is designed for protection against lightning strikes and other transient phenomena on power lines, but also against disturbances in the mains. Nominal Voltage (Un): The nominal voltage stands for the nominal voltage of the system to be protected Maximum Continuous Operating Voltage (Uc): The maximum continuous operating voltage is the r.m.s value of the maximum voltage which may be connected to corresponding terminals of the Surge Protective Device during operations Maximum Continuous Operating Voltage for PV System (Ucpv): The maximum continuous operating voltage for Photovoltaic (PC) system is the value of the maximum DC voltage which may be permanently applied to terminals of SPD. The Ucpv shall be specified in terms of nominal voltage, nominal current, floating voltage, and floating current. Voltage Protection Level (Up): The Voltage Protection Level is the maximum instantaneous value of the voltage at terminals of SPD. It shall be specified in terms of nominal voltage, nominal current, floating voltage, and floating current. Nominal Discharge Current (In): The nominal discharge current is the peak value of the current that can be passed through SPD having a wave shape of 8/20 µs. It shall be specified in terms of nominal voltage, nominal current, floating voltage, and floating current. Maximum Discharge Current (Imax): The maximum discharge current is the peak value of the current which the device can safely discharge through the SPD having a wave shape of 8/20 µs. It shall be specified in terms of nominal Applications Photovoltaic & Wind Industry & Automation Commercial & Residential Installations Telecom, IT & Data Centers
₹2,005  
AC Surge Protection Device (SPD) is designed to limit transient over voltages of atmospheric origin and divert current waves to earth, so as to limit the amplitude of this over voltage to a value that is not hazardous for the electrical installation and electric switchgear. Type 2 SPD: The Type 2 SPD is the main protection system for all low voltage electrical installations. Installed in each electrical switchboard, it prevents the spread of over voltages in the electrical installations and protects the load. Nominal Voltage (Un): The nominal voltage stands for the nominal voltage of the system to be protected Maximum Continuous Operating Voltage (Uc): The maximum continuous operating voltage is the r.m.s value of the maximum voltage which may be connected to corresponding terminals of the Surge Protective Device during operations.
The maximum continuous operating voltage for Photovoltaic (PC) system is the value of the maximum DC voltage which may be permanently applied to terminals of SPD. The voltage protection level (Up), nominal discharge current (In) and maximum discharge current (Imax) are defined as follows: Voltage Protection Level (Up): The Voltage Protection Level is the maximum instantaneous value of the voltage at terminals of SPD. Nominal Discharge Current (In): The nominal discharge current is the peak value of the current that can be passed through SPD having a wave shape of 8/20 µs. Applications Photovoltaic & Wind Industry & Automation Commercial & Residential Installations Telecom, IT & Data Centers
Recommended Items
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
Browsing History
sku-leadTime Ships within 5 days
sku-leadTime Ships within 7 days
sku-leadTime Ships within 3 days
sku-leadTime Ships within 7 days
sku-leadTime Ships within 10 days
sku-leadTime Ships within 6 days
₹44,099 ₹54,600
19.23% OFF
RELATED CATEGORIES OF ELMEX SOLAR SURGE PROTECTION DEVICE
EXPLORE BRANDS RELATED TO ELMEX

Top Selling Elmex Solar Surge Protection Device Products Price List for March 2026

This data was last updated on 19/03/2026