Filter

Categories
Price Range
Min Price:
Max Price:
₹
-
₹
Discount
Import Country
Availability
Country of Origin
Express Shipping

Omron Limit Switches

Showing 40 out of 1253 products

Sort by
₹2,241  
Features:LoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2.5 A(NC) 1.25 A(NO)
Rated voltage: 480 VAC / Resistive load: 3 A(NC) 3 A(NO) / Lamp load: 1.5 A(NC) 0.75 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 250 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 3 A(NC) 1.5 A(NO)
Rated voltage: 480 VAC / Inductive load: 2.5 A(NC) 2.5 A(NO) / Motor load: 1.5 A(NC) 0.75 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 30 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.5 A(NC) 0.5 A(NO) / Lamp load: 0.4 A(NC) 0.4 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.25 A(NC) 0.25 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 14 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 30 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.05 A(NC) 0.05 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.03 A(NC) 0.03 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Permissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 20 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 2,000 VAC 50/60 Hz for 1 minMechanical durability10,000,000 operations min.Electrical durability500,000 operations min.
nullVibration resistance (Malfunction)10 to 55 Hz, 1.5-mm double amplitude, Contact opening: 1 ms max. at the free position and the total travel position.Shock resistanceDestruction: 1000 m/s2 max.Movement DifferentialStandard value 3 mm max.Free Position Standard value 51 mm max.
₹10,855  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 3 ° max.
₹10,619  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹4,129  
Features:LoadGeneral loadRatings (AC): Non-Inductive loadRated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 480 VAC / Resistive load: 2 A(NC) 2 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO)Ratings (AC): Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 2.5 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 1.5 A(NO)Ratings (DC): Non-Inductive loadRated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.4 A(NC) 0.4 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO)Ratings (DC): Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Inductive load: 1.5 A(NC) 1.5 A(NO) / Motor load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.05 A(NC) 0.05 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.03 A(NC) 0.03 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class II (Grounding not required with double) insulation
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Permissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 2,000 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability500,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 300 m/s2 max.Movement DifferentialStandard value 0.5 mm max.
₹8,967  
Features:Electrical ratings4 A at 30 VDCLoadGeneral loadRatings (DC): Non-Inductive loadRated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)Ratings (DC): Inductive loadRated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 30 VDC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability110,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability1,000,000 operations min. (0.1 A at 30 VDC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 3 ° max.
₹8,495  
Features:Electrical ratings4 A at 30 VDCLoadGeneral loadRatings (DC): Non-Inductive loadRated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)Ratings (DC): Inductive loadRated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 30 VDC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability110,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability1,000,000 operations min. (0.1 A at 30 VDC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 3 ° max.
₹6,371  
Features:Electrical ratings4 A at 30 VDCLoadGeneral loadRatings (DC): Non-Inductive loadRated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)Ratings (DC): Inductive loadRated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 30 VDC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability110,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability1,000,000 operations min. (0.1 A at 30 VDC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹8,023  
Features:Electrical ratings4 A at 30 VDCLoadGeneral loadRatings (DC): Non-Inductive loadRated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)Ratings (DC): Inductive loadRated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 30 VDC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability110,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability1,000,000 operations min. (0.1 A at 30 VDC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹8,613  
Features:Electrical ratings5 A at 125 VACLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 125 VAC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 3 ° max.
₹8,967  
Features:Electrical ratings5 A at 125 VACLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 125 VAC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹8,023  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹7,079  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹10,029  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹8,495  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 3 ° max.
₹8,259  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹8,731  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹8,731  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹7,315  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 3 ° max.
₹7,197  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹6,725  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹5,663  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹15,339  
Features:LoadGeneral loadContact configuration4-circuit double break typeRatings (AC): Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 250 VAC / Resistive load: 3 A(NC) 3 A(NO) / Lamp load: 1 A(NC) 1 A(NO)
Rated voltage: 480 VAC / Resistive load: 1.5 A(NC) 1.5 A(NO) / Lamp load: 0.5 A(NC) 0.5 A(NO)
Rated voltage: 600 VAC / Resistive load: 1 A(NC) 1 A(NO) / Lamp load: 0.4 A(NC) 0.4 A(NO)Ratings (AC): Inductive loadRated voltage: 125 VAC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 1.5 A(NO
Rated voltage: 480 VAC / Inductive load: 1 A(NC) 1 A(NO) / Motor load: 0.8 A(NC) 0.8 A(NO)
Rated voltage: 600 VAC / Inductive load: 0.7 A(NC) 0.7 A(NO) / Motor load: 0.5 A(NC) 0.5 A(NO)Ratings (DC): Non-Inductive loadRated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 3 A(NC) 3 A(NO) / Lamp load: 1 A(NC) 1 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.1 A(NC) 0.1 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)Ratings (DC): Inductive loadRated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.1 A(NC) 0.1 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)Protective circuitClassification of protection against electric shock: Class I (with ground terminal)Conduit sizeG1/2Permissible operating frequency Mechanically: 300 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Insulation resistanceBetween each terminal of the same polarities: 100 MΩ min.
Between live-metallic part and ground: 100 MΩ min.
Between each terminal and non-live-metallic part: 100 MΩ min. (at 500 VDC)Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 2,200 VAC 50/60 Hz 1 min
Between each terminal and non-live-metallic part: 2,200 VAC 50/60 Hz 1 minMechanical durability30,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability750,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 300 m/s2 max..Pre-TravelStandard value 19 ° max.
Average value 15 ° max.Movement DifferentialStandard value 5 ° max.
Average value 4 ° max.
₹17,699  
Features:Operation typeSimultaneous operation typeLoadGeneral loadContact configuration4-circuit double break typeRatings (AC): Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 250 VAC / Resistive load: 3 A(NC) 3 A(NO) / Lamp load: 1 A(NC) 1 A(NO)
Rated voltage: 480 VAC / Resistive load: 1.5 A(NC) 1.5 A(NO) / Lamp load: 0.5 A(NC) 0.5 A(NO)
Rated voltage: 600 VAC / Resistive load: 1 A(NC) 1 A(NO) / Lamp load: 0.4 A(NC) 0.4 A(NO)Ratings (AC): Inductive loadRated voltage: 125 VAC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 1.5 A(NO
Rated voltage: 480 VAC / Inductive load: 1 A(NC) 1 A(NO) / Motor load: 0.8 A(NC) 0.8 A(NO)
Rated voltage: 600 VAC / Inductive load: 0.7 A(NC) 0.7 A(NO) / Motor load: 0.5 A(NC) 0.5 A(NO)Ratings (DC): Non-Inductive loadRated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 3 A(NC) 3 A(NO) / Lamp load: 1 A(NC) 1 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.1 A(NC) 0.1 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)Ratings (DC): Inductive loadRated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.1 A(NC) 0.1 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)Protective circuitClassification of protection against electric shock: Class I (with ground terminal)Conduit sizeG1/2Permissible operating frequency Mechanically: 300 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Insulation resistanceBetween each terminal of the same polarities: 100 MΩ min.
Between live-metallic part and ground: 100 MΩ min.
Between each terminal and non-live-metallic part: 100 MΩ min. (at 500 VDC)Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 2,200 VAC 50/60 Hz 1 min
Between each terminal and non-live-metallic part: 2,200 VAC 50/60 Hz 1 minMechanical durability30,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability750,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 300 m/s2 max..Pre-TravelStandard value 15 ° max.
Average value 12 ° max.Movement DifferentialStandard value 7 ° max.
Average value 6 ° max.
₹10,265  
Features:LoadGeneral loadContact configuration2-circuit double break typeRatings (AC): Non-Inductive loadRated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2 A(NC) 1 A(NO)
Rated voltage: 480 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 1.5 A(NC) 0.8 A(NO)
Rated voltage: 600 VAC / Resistive load: 3 A(NC) 1 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC): Inductive loadRated voltage: 125 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 250 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 3 A(NC) 1.5 A(NO)
Rated voltage: 480 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)
Rated voltage: 600 VAC / Inductive load: 1.5 A(NC) 1.5 A(NO) / Motor load: 1 A(NC) 0.5 A(NO)Ratings (DC): Non-Inductive loadRated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 6 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 6 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 4 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.8 A(NC) 0.8 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.1 A(NC) 0.1 A(NO)Ratings (DC): Inductive loadRated voltage: 8 VDC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 6 A(NC) 6 A(NO)
Rated voltage: 14 VDC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 6 A(NC) 6 A(NO)
Rated voltage: 30 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 4 A(NC) 4 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.8 A(NC) 0.8 A(NO) / Motor load: 0.2 A(NC) 0.2 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.1 A(NC) 0.1 A(NO)Protective circuitClassification of protection against electric shock: Class I (with ground terminal)Conduit sizeG1/2Permissible operating frequency Mechanically: 300 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Insulation resistanceBetween each terminal of the same polarities: 100 MΩ min.
Between live-metallic part and ground: 100 MΩ min.
Between each terminal and non-live-metallic part: 100 MΩ min. (at 500 VDC)Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 2,200 VAC 50/60 Hz 1 min
Between each terminal and non-live-metallic part: 2,200 VAC 50/60 Hz 1 minMechanical durability50,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability1,000,000 operations min. (10 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 600 m/s2 max..Pre-TravelStandard value 15 ° max.
Average value 12 ° max.Movement DifferentialStandard value 5 ° max.
Average value 4 ° max.
Recommended Items
oos-available Ships within 24 hrs
sku-leadTime Ships within 10 days
21
Pack of 40 piece
₹110 ₹110
0.01% OFF
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
sku-leadTime Ships within 10 days
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
Browsing History
sku-leadTime Ships within 5 days
sku-leadTime Ships within 7 days
sku-leadTime Ships within 3 days
sku-leadTime Ships within 7 days
sku-leadTime Ships within 10 days
sku-leadTime Ships within 3 days

Top Selling Omron Limit Switches Products Price List for August 2026

This data was last updated on 10/08/2026