Omron Miniature Basic Switch Hinge, Roller, Lever Type Actuator 10 A Rated Current is designed to provide reliable switching and mechanical actuation for industrial automation, machinery, and electrical control applications. With a rated current of 10 A, this miniature basic switch is suitable for compatible electrical circuits requiring dependable switching performance. Its hinge, roller, and lever actuator configuration enables responsive operation through suitable mechanical movement or contact. The compact design supports convenient integration into compatible equipment and machinery where reliable mechanical sensing and consistent switching are required. The Omron Miniature Basic Switch Hinge, Roller, Lever Type Actuator 10 A Rated Current is suitable for industrial machinery, automation equipment, production systems, control mechanisms, and position-sensing applications. Its roller lever configuration allows convenient mechanical engagement while supporting reliable operation during repeated switching cycles. Manufactured by Omron, this miniature basic switch is designed for professional applications requiring dependable electrical switching, responsive mechanical actuation, and compact installation. It provides a practical solution for equipment manufacturers, automation system integrators, and maintenance professionals working with compatible industrial switching applications.
green checkType of Product : Miniature Basic Switch
green checkRated Voltage (V) : AC 250
green checkRated Current (A) : 10 A
green checkActuator Type : Hinge, Roller, Lever Type
Related Searches
omron switch accessories
omron limit switches
omron push button switches
omron basic switch
omron selector switches
₹258 - ₹1,887
Omron Seal-Type Ultra-Compact Basic Switch DC 30 Rated Voltage Hinge/Roller/Lever Type Actuator D2SW Type is designed for reliable electrical switching and mechanical actuation in compact industrial and electronic applications. Featuring a sealed construction and ultra-compact design, this D2SW Type basic switch provides practical protection for suitable operating environments while supporting dependable switching performance. The hinge, roller, and lever actuator configuration enables responsive operation through suitable mechanical movement or contact, making it suitable for compatible equipment requiring compact and consistent actuation. With a DC 30V rated voltage, it is designed for use in compatible low-voltage electrical switching circuits. The Omron Seal-Type Ultra-Compact Basic Switch DC 30 Rated Voltage Hinge/Roller/Lever Type Actuator D2SW Type is suitable for industrial equipment, automation systems, control mechanisms, electronic devices, and position-sensing applications. Its roller lever arrangement supports convenient mechanical engagement and reliable operation during repeated switching cycles. Manufactured by Omron, this D2SW Type basic switch provides a practical solution for equipment manufacturers, automation system integrators, and maintenance professionals requiring reliable electrical switching, compact construction, sealed protection, and responsive mechanical actuation.
green checkType of Product : Seal-Type Ultra-Compact Basic Switch
green checkRated Voltage (V) : DC 30
green checkRated Current (A) : 0.1
green checkElectric Shock Protection Class : Class I
green checkActuator Type : Hinge / roller / lever type
green checkPTI (Proof Tracking Index) : 175
green checkInrush current (A) : Normally closed circuit: max. 1, normally open circuit: max. 1
green checkElectrical Durability : 200,000 operations or more (30 operations / min)
₹2,595 - ₹3,303
The Omron Push Button Switch is engineered for industrial and automation applications, delivering reliable performance and easy installation. It is available in alternate and momentary operation types, ensuring versatility for various control systems. This terminal block enables quick and secure wiring. Offered in multiple button shapes—round (flat), mushroom, round (full guard type), protruding, and standard round—this switch suits diverse applications. Its rugged construction ensures long-lasting durability in demanding environments, making it the perfect choice for control panels, machinery, and industrial automation systems.
green checkColor : Yellow
green checkType of Product : Pushbutton Switch
green checkInsulation Resistance : 100 mΩ or more (with DC500 V Mega)
green checkProtection Class : IP65 Oil Resistant Type (from Front of Panel)
green checkShock Resistance : 500 m/s²
green checkFunction : Non-Illuminated, Push-Lock Turn Reset
green checkAmbient Humidity to Use : 35~85%RH
green checkStorage Temperature : -25° to +65° (with No Icing or Condensation)
green checkOperation Ambient Temperature : -10°C to +55°C (with No Icing or Condensation)
green checkMechanical Durability : 100000 Times or more
green checkElectrical Durability : 100000 Times or more
green checkLight Source : Non-illuminated
green checkCountry of Origin : Japan
green checkTerminal Type : Solder Terminal
green checkVibration Resistance (Malfunction) : 10 to 55 Hz Double Amplitude 1.5 mm (Malfunction 1 ms or less)
green checkShock Resistance (Malfunction) : 300 m/s² (Malfunction within 1 ms)
green checkMounting Hole Diameter : Φ16 mm
₹2,241  
Features:LoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2.5 A(NC) 1.25 A(NO)
Rated voltage: 480 VAC / Resistive load: 3 A(NC) 3 A(NO) / Lamp load: 1.5 A(NC) 0.75 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 250 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 3 A(NC) 1.5 A(NO)
Rated voltage: 480 VAC / Inductive load: 2.5 A(NC) 2.5 A(NO) / Motor load: 1.5 A(NC) 0.75 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 30 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.5 A(NC) 0.5 A(NO) / Lamp load: 0.4 A(NC) 0.4 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.25 A(NC) 0.25 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 14 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 30 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.05 A(NC) 0.05 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.03 A(NC) 0.03 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Permissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 20 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 2,000 VAC 50/60 Hz for 1 minMechanical durability10,000,000 operations min.Electrical durability500,000 operations min.
nullVibration resistance (Malfunction)10 to 55 Hz, 1.5-mm double amplitude, Contact opening: 1 ms max. at the free position and the total travel position.Shock resistanceDestruction: 1000 m/s2 max.Movement DifferentialStandard value 3 mm max.Free Position Standard value 51 mm max.
₹2,005  
The Omron Operation Key For Use With D4GS-N Series, D4GS-NK2 is a key component of this safety mechanism.
The safety door switch typically consists of a switch unit installed on the door or access point and a control unit connected to the machinery. The Operation Key is a physical key that is used to engage or disengage the safety switch. When the key is inserted and turned, it allows the switch to close, signaling that the door is securely closed and the equipment can operate safely. Without the key in place, the switch remains open, preventing the machinery from functioning.
This key-based system serves as a physical barrier to ensure that only authorized personnel with the correct key can enable the equipment. It adds an extra layer of security, as it requires a deliberate action to insert and turn the key, reducing the risk of accidental or unauthorized access to the machinery.
In emergency situations or during maintenance, the Operation Key can be easily removed, instantly interrupting the power supply to the machinery and ensuring a safe shutdown. This feature is crucial for compliance with safety standards and regulations governing industrial machinery.
Overall, the Operation Key for a safety door switch is a simple yet effective means of enhancing workplace safety by controlling access to hazardous machinery and preventing unintended operation, contributing to the protection of personnel and the integrity of industrial processes.
₹11,327  
The Omron AC/DC Power Supply Free Type Photoelectric Switch, specifically the E3JK model, represents a state-of-the-art optical sensing solution meticulously engineered for a diverse range of industrial and automation applications. This cutting-edge sensor excels in object detection without reliance on an external power supply, offering inherent energy efficiency and a cost-effective proposition for industrial settings. This particular variant from Omron has been meticulously designed to operate seamlessly with both alternating current (AC) and direct current (DC) power sources, showcasing remarkable adaptability to varying electrical systems. This versatility makes it a preferred choice for integrators and engineers working in environments with mixed power infrastructure. Fundamentally, the E3JK utilizes advanced optical technology, often incorporating infrared or visible light sources combined with a photosensitive receiver. When an object traverses the emitted light beam, it disrupts the beam, eliciting an immediate signal from the sensor. This signal is instrumental in activating or deactivating specific functions or processes within the control system, encompassing applications such as conveyor system control, object quantification, and obstruction detection in automated manufacturing environments. A salient feature of the E3JK is its 'power supply-free' operation, eliminating the need for an external power source. This not only simplifies installation but also bolsters energy efficiency, reducing operational costs. Omron's commitment to quality engineering ensures consistent, precise, and reliable performance, making the E3JK an ideal choice for professionals seeking dependable optoelectronic sensing solutions in the industrial sector.
₹24,779  
The Omron Small Electromagnetic Lock Safety Door Switch D4NL is a fundamental component in the realm of industrial safety systems, meticulously engineered to provide reliable and precise safety interlocking solutions. Developed by Omron, a globally recognized leader in automation and control technologies, the D4NL model is designed to adhere to stringent safety standards and cater to diverse industrial and commercial applications. The distinguishing feature of the D4NL Safety Door Switch is its integration of a small electromagnetic lock within the switch mechanism. This design ensures a secure and tamper-proof safety interlock system. When the safety door is properly closed and the D4NL switch is actuated, the electromagnetic lock engages, holding the door securely in place. This mechanism is pivotal for applications where personnel protection and equipment integrity are of paramount concern, as it prevents unauthorized access to hazardous machinery. The D4NL Safety Door Switch includes various advanced safety features, such as positively driven contacts that ensure a fail-safe operation. These contacts remain open when the switch is actuated, preventing unintended access or bypassing of the safety interlock system, thereby aligning with the strictest safety regulations and standards. The switch is engineered for high precision and durability, with a robust construction capable of withstanding mechanical stress and environmental factors. Its adaptability is further enhanced by various actuator options, allowing for versatile installation and compatibility with a range of safety door configurations. The Omron Small Electromagnetic Lock Safety Door Switch D4NL is a testament to Omron's commitment to safety, quality, and innovation. Its integration of an electromagnetic lock, advanced safety features, and adaptability in actuator options make it an indispensable component for professionals seeking a dependable safety solution in industrial environments where operator protection and equipment safeguarding are of paramount importance.
₹21,239  
The Omron Small Electromagnetic Lock Safety Door Switch D4NL is a fundamental component in the realm of industrial safety systems, meticulously engineered to provide reliable and precise safety interlocking solutions. Developed by Omron, a globally recognized leader in automation and control technologies, the D4NL model is designed to adhere to stringent safety standards and cater to diverse industrial and commercial applications. The distinguishing feature of the D4NL Safety Door Switch is its integration of a small electromagnetic lock within the switch mechanism. This design ensures a secure and tamper-proof safety interlock system. When the safety door is properly closed and the D4NL switch is actuated, the electromagnetic lock engages, holding the door securely in place. This mechanism is pivotal for applications where personnel protection and equipment integrity are of paramount concern, as it prevents unauthorized access to hazardous machinery. The D4NL Safety Door Switch includes various advanced safety features, such as positively driven contacts that ensure a fail-safe operation. These contacts remain open when the switch is actuated, preventing unintended access or bypassing of the safety interlock system, thereby aligning with the strictest safety regulations and standards. The switch is engineered for high precision and durability, with a robust construction capable of withstanding mechanical stress and environmental factors. Its adaptability is further enhanced by various actuator options, allowing for versatile installation and compatibility with a range of safety door configurations. The Omron Small Electromagnetic Lock Safety Door Switch D4NL is a testament to Omron's commitment to safety, quality, and innovation. Its integration of an electromagnetic lock, advanced safety features, and adaptability in actuator options make it an indispensable component for professionals seeking a dependable safety solution in industrial environments where operator protection and equipment safeguarding are of paramount importance.
₹15,339 - ₹29,499
Omron Electromagnetic Door Switch, Connector Connection Type, 6 Contact Configuration (In-built Switch: 3NC + 3NC) is engineered to provide reliable safety interlocking and accurate door position monitoring for industrial machinery and automated production systems. Designed with a connector connection type for quick installation and simplified maintenance, this electromagnetic door switch features a 6-contact configuration comprising two independent sets of three normally closed (NC) contacts. It is ideal for machine guards, safety gates, access doors, robotic systems, automated production lines, and industrial equipment where fail-safe safety monitoring is essential. Built to Omron’s globally trusted engineering standards, the Omron Electromagnetic Door Switch, Connector Connection Type, 6 Contact Configuration (In-built Switch: 3NC + 3NC) delivers stable switching performance, excellent mechanical durability, and long operational life under demanding industrial conditions. The connector-based design minimizes wiring time and enables fast replacement during maintenance, while the multiple NC contacts integrate seamlessly with safety relays, PLCs, and machine control systems. Trusted by engineers, automation specialists, and maintenance professionals, this Omron electromagnetic door switch enhances workplace safety, improves equipment reliability, and supports efficient industrial automation across a wide range of applications.
green checkRated Frequency (Hz) : 50/60 Hz
green checkMechanical Durability : 10 Million Times or More
green checkOperation Ambient Temperature : -10 to 55℃
green checkInsulation Resistance : 100 or more (with DC500V mega)
green checkMinimum Applicable Load : DC5V 1mA resistance load (N level reference value)
green checkAmbient Humidity to Use : 95% RH or less
green checkContact Resistance : 200 mΩ or Less
green checkIn-built Switch : 3NC+3NC
green checkConnection Type : Connector
green checkContact Configuration : 6 Contacts
green checkVibration Resistance (Malfunction) : 10~55Hz one amplitude 0.35mm
green checkRated Voltage (V) : DC24
₹25,959  
The Omron Small Electromagnetic Lock Safety Door Switch D4NL is a fundamental component in the realm of industrial safety systems, meticulously engineered to provide reliable and precise safety interlocking solutions. Developed by Omron, a globally recognized leader in automation and control technologies, the D4NL model is designed to adhere to stringent safety standards and cater to diverse industrial and commercial applications. The distinguishing feature of the D4NL Safety Door Switch is its integration of a small electromagnetic lock within the switch mechanism. This design ensures a secure and tamper-proof safety interlock system. When the safety door is properly closed and the D4NL switch is actuated, the electromagnetic lock engages, holding the door securely in place. This mechanism is pivotal for applications where personnel protection and equipment integrity are of paramount concern, as it prevents unauthorized access to hazardous machinery. The D4NL Safety Door Switch includes various advanced safety features, such as positively driven contacts that ensure a fail-safe operation. These contacts remain open when the switch is actuated, preventing unintended access or bypassing of the safety interlock system, thereby aligning with the strictest safety regulations and standards. The switch is engineered for high precision and durability, with a robust construction capable of withstanding mechanical stress and environmental factors. Its adaptability is further enhanced by various actuator options, allowing for versatile installation and compatibility with a range of safety door configurations. The Omron Small Electromagnetic Lock Safety Door Switch D4NL is a testament to Omron's commitment to safety, quality, and innovation. Its integration of an electromagnetic lock, advanced safety features, and adaptability in actuator options make it an indispensable component for professionals seeking a dependable safety solution in industrial environments where operator protection and equipment safeguarding are of paramount importance.
₹23,599  
The Omron Small Electromagnetic Lock Safety Door Switch D4NL is a fundamental component in the realm of industrial safety systems, meticulously engineered to provide reliable and precise safety interlocking solutions. Developed by Omron, a globally recognized leader in automation and control technologies, the D4NL model is designed to adhere to stringent safety standards and cater to diverse industrial and commercial applications. The distinguishing feature of the D4NL Safety Door Switch is its integration of a small electromagnetic lock within the switch mechanism. This design ensures a secure and tamper-proof safety interlock system. When the safety door is properly closed and the D4NL switch is actuated, the electromagnetic lock engages, holding the door securely in place. This mechanism is pivotal for applications where personnel protection and equipment integrity are of paramount concern, as it prevents unauthorized access to hazardous machinery. The D4NL Safety Door Switch includes various advanced safety features, such as positively driven contacts that ensure a fail-safe operation. These contacts remain open when the switch is actuated, preventing unintended access or bypassing of the safety interlock system, thereby aligning with the strictest safety regulations and standards. The switch is engineered for high precision and durability, with a robust construction capable of withstanding mechanical stress and environmental factors. Its adaptability is further enhanced by various actuator options, allowing for versatile installation and compatibility with a range of safety door configurations. The Omron Small Electromagnetic Lock Safety Door Switch D4NL is a testament to Omron's commitment to safety, quality, and innovation. Its integration of an electromagnetic lock, advanced safety features, and adaptability in actuator options make it an indispensable component for professionals seeking a dependable safety solution in industrial environments where operator protection and equipment safeguarding are of paramount importance.
₹10,855  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 3 ° max.
₹10,619  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹4,129  
Features:LoadGeneral loadRatings (AC): Non-Inductive loadRated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 480 VAC / Resistive load: 2 A(NC) 2 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO)Ratings (AC): Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 2.5 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 1.5 A(NO)Ratings (DC): Non-Inductive loadRated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.4 A(NC) 0.4 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO)Ratings (DC): Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Inductive load: 1.5 A(NC) 1.5 A(NO) / Motor load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.05 A(NC) 0.05 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.03 A(NC) 0.03 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class II (Grounding not required with double) insulation
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Permissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 2,000 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability500,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 300 m/s2 max.Movement DifferentialStandard value 0.5 mm max.
₹8,967  
Features:Electrical ratings4 A at 30 VDCLoadGeneral loadRatings (DC): Non-Inductive loadRated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)Ratings (DC): Inductive loadRated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 30 VDC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability110,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability1,000,000 operations min. (0.1 A at 30 VDC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 3 ° max.
₹8,495  
Features:Electrical ratings4 A at 30 VDCLoadGeneral loadRatings (DC): Non-Inductive loadRated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)Ratings (DC): Inductive loadRated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 30 VDC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability110,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability1,000,000 operations min. (0.1 A at 30 VDC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 3 ° max.
₹6,371  
Features:Electrical ratings4 A at 30 VDCLoadGeneral loadRatings (DC): Non-Inductive loadRated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)Ratings (DC): Inductive loadRated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 30 VDC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability110,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability1,000,000 operations min. (0.1 A at 30 VDC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹8,023  
Features:Electrical ratings4 A at 30 VDCLoadGeneral loadRatings (DC): Non-Inductive loadRated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)Ratings (DC): Inductive loadRated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 30 VDC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability110,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability1,000,000 operations min. (0.1 A at 30 VDC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹8,613  
Features:Electrical ratings5 A at 125 VACLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 125 VAC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 3 ° max.
₹8,967  
Features:Electrical ratings5 A at 125 VACLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 125 VAC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹8,023  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹7,079  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹10,029  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
Recommended Items
oos-available Ships within 24 hrs
sku-leadTime Ships within 10 days
21
Pack of 40 piece
₹110 ₹110
0.01% OFF
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
sku-leadTime Ships within 10 days
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
Browsing History
sku-leadTime Ships within 5 days
sku-leadTime Ships within 7 days
sku-leadTime Ships within 3 days
sku-leadTime Ships within 7 days
sku-leadTime Ships within 10 days