Omron Miniature Basic Switch Hinge, Roller, Lever Type Actuator 10 A Rated Current is designed to provide reliable switching and mechanical actuation for industrial automation, machinery, and electrical control applications. With a rated current of 10 A, this miniature basic switch is suitable for compatible electrical circuits requiring dependable switching performance. Its hinge, roller, and lever actuator configuration enables responsive operation through suitable mechanical movement or contact. The compact design supports convenient integration into compatible equipment and machinery where reliable mechanical sensing and consistent switching are required. The Omron Miniature Basic Switch Hinge, Roller, Lever Type Actuator 10 A Rated Current is suitable for industrial machinery, automation equipment, production systems, control mechanisms, and position-sensing applications. Its roller lever configuration allows convenient mechanical engagement while supporting reliable operation during repeated switching cycles. Manufactured by Omron, this miniature basic switch is designed for professional applications requiring dependable electrical switching, responsive mechanical actuation, and compact installation. It provides a practical solution for equipment manufacturers, automation system integrators, and maintenance professionals working with compatible industrial switching applications.
green checkType of Product : Miniature Basic Switch
green checkRated Voltage (V) : AC 250
green checkRated Current (A) : 10 A
green checkActuator Type : Hinge, Roller, Lever Type
Related Searches
omron limit switches
omron electromagnetic switches
omron push button switches
omron basic switch
omron selector switches
₹9,675 - ₹40,119
The Omron Floatless switch (Base Type) 61F-G Series is designed for automatic liquid-level detection and control applications where reliable electrical sensing is required. Unlike conventional mechanical float mechanisms, floatless switching technology uses liquid conductivity detection to determine level conditions and support control operations. The base-type configuration provides a suitable foundation for integration into compatible control systems and liquid-management equipment. The 61F-G Series is commonly suited to applications involving water supply, drainage, tanks, reservoirs, and pump control, making it a practical component for industrial and commercial liquid-level management. The Omron Floatless switch (Base Type) 61F-G Series can be incorporated into water-level control panels, pumping installations, industrial equipment, and systems requiring automatic monitoring of conductive liquids. Its floatless approach helps eliminate dependence on moving float assemblies, providing a practical sensing method for suitable applications. The base-type design allows system designers to configure the switch within compatible control arrangements according to equipment requirements. Manufactured by Omron, this 61F-G Series solution is suitable for automation engineers, equipment manufacturers, and maintenance professionals seeking dependable liquid-level control technology for tanks, reservoirs, and water-handling systems.
green checkType of Product : Floatless switch (Base Type)
green checkSeries : 61F-G Series
₹258 - ₹1,887
Omron Seal-Type Ultra-Compact Basic Switch DC 30 Rated Voltage Hinge/Roller/Lever Type Actuator D2SW Type is designed for reliable electrical switching and mechanical actuation in compact industrial and electronic applications. Featuring a sealed construction and ultra-compact design, this D2SW Type basic switch provides practical protection for suitable operating environments while supporting dependable switching performance. The hinge, roller, and lever actuator configuration enables responsive operation through suitable mechanical movement or contact, making it suitable for compatible equipment requiring compact and consistent actuation. With a DC 30V rated voltage, it is designed for use in compatible low-voltage electrical switching circuits. The Omron Seal-Type Ultra-Compact Basic Switch DC 30 Rated Voltage Hinge/Roller/Lever Type Actuator D2SW Type is suitable for industrial equipment, automation systems, control mechanisms, electronic devices, and position-sensing applications. Its roller lever arrangement supports convenient mechanical engagement and reliable operation during repeated switching cycles. Manufactured by Omron, this D2SW Type basic switch provides a practical solution for equipment manufacturers, automation system integrators, and maintenance professionals requiring reliable electrical switching, compact construction, sealed protection, and responsive mechanical actuation.
green checkType of Product : Seal-Type Ultra-Compact Basic Switch
green checkRated Voltage (V) : DC 30
green checkRated Current (A) : 0.1
green checkElectric Shock Protection Class : Class I
green checkActuator Type : Hinge / roller / lever type
green checkPTI (Proof Tracking Index) : 175
green checkInrush current (A) : Normally closed circuit: max. 1, normally open circuit: max. 1
green checkElectrical Durability : 200,000 operations or more (30 operations / min)
₹2,595 - ₹3,303
The Omron Push Button Switch is engineered for industrial and automation applications, delivering reliable performance and easy installation. It is available in alternate and momentary operation types, ensuring versatility for various control systems. This terminal block enables quick and secure wiring. Offered in multiple button shapes—round (flat), mushroom, round (full guard type), protruding, and standard round—this switch suits diverse applications. Its rugged construction ensures long-lasting durability in demanding environments, making it the perfect choice for control panels, machinery, and industrial automation systems.
green checkColor : Yellow
green checkType of Product : Pushbutton Switch
green checkInsulation Resistance : 100 mΩ or more (with DC500 V Mega)
green checkProtection Class : IP65 Oil Resistant Type (from Front of Panel)
green checkShock Resistance : 500 m/s²
green checkFunction : Non-Illuminated, Push-Lock Turn Reset
green checkAmbient Humidity to Use : 35~85%RH
green checkStorage Temperature : -25° to +65° (with No Icing or Condensation)
green checkOperation Ambient Temperature : -10°C to +55°C (with No Icing or Condensation)
green checkMechanical Durability : 100000 Times or more
green checkElectrical Durability : 100000 Times or more
green checkLight Source : Non-illuminated
green checkCountry of Origin : Japan
green checkTerminal Type : Solder Terminal
green checkVibration Resistance (Malfunction) : 10 to 55 Hz Double Amplitude 1.5 mm (Malfunction 1 ms or less)
green checkShock Resistance (Malfunction) : 300 m/s² (Malfunction within 1 ms)
green checkMounting Hole Diameter : Φ16 mm
₹3,067  
The Omron Operation Key For Use With D4GS-N Series, D4GS-NK2 is a key component of this safety mechanism.
The safety door switch typically consists of a switch unit installed on the door or access point and a control unit connected to the machinery. The Operation Key is a physical key that is used to engage or disengage the safety switch. When the key is inserted and turned, it allows the switch to close, signaling that the door is securely closed and the equipment can operate safely. Without the key in place, the switch remains open, preventing the machinery from functioning.
This key-based system serves as a physical barrier to ensure that only authorized personnel with the correct key can enable the equipment. It adds an extra layer of security, as it requires a deliberate action to insert and turn the key, reducing the risk of accidental or unauthorized access to the machinery.
In emergency situations or during maintenance, the Operation Key can be easily removed, instantly interrupting the power supply to the machinery and ensuring a safe shutdown. This feature is crucial for compliance with safety standards and regulations governing industrial machinery.
Overall, the Operation Key for a safety door switch is a simple yet effective means of enhancing workplace safety by controlling access to hazardous machinery and preventing unintended operation, contributing to the protection of personnel and the integrity of industrial processes.
₹2,359  
Features:LoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2.5 A(NC) 1.25 A(NO)
Rated voltage: 480 VAC / Resistive load: 3 A(NC) 3 A(NO) / Lamp load: 1.5 A(NC) 0.75 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 250 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 3 A(NC) 1.5 A(NO)
Rated voltage: 480 VAC / Inductive load: 2.5 A(NC) 2.5 A(NO) / Motor load: 1.5 A(NC) 0.75 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 30 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.5 A(NC) 0.5 A(NO) / Lamp load: 0.4 A(NC) 0.4 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.25 A(NC) 0.25 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 14 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 30 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.05 A(NC) 0.05 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.03 A(NC) 0.03 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Permissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 20 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 2,000 VAC 50/60 Hz for 1 minMechanical durability10,000,000 operations min.Electrical durability500,000 operations min.
nullVibration resistance (Malfunction)10 to 55 Hz, 1.5-mm double amplitude, Contact opening: 1 ms max. at the free position and the total travel position.Shock resistanceDestruction: 1000 m/s2 max.Movement DifferentialStandard value 3 mm max.Free Position Standard value 51 mm max.
₹5,899 - ₹18,879
The Omron AC/DC Power-Free Type Photoelectric Switch ABS Case, E3JK Series (Cable Length: 2-5 m) is designed for reliable object detection in industrial automation and machine-control applications. Featuring an AC/DC power-compatible design, power-free switching functionality, and a durable ABS case, this photoelectric switch provides a practical sensing solution for detecting objects without direct physical contact. The E3JK Series supports cable lengths from 2 to 5 m, offering flexibility for different equipment layouts and installation distances. Its compact construction makes it suitable for integration into machinery, conveyor systems, production lines, and automated material-handling equipment. The Omron AC/DC Power-Free Type Photoelectric Switch ABS Case, E3JK Series (Cable Length: 2-5 m) is suitable for manufacturing equipment, packaging machinery, conveyor systems, automated production lines, and object-detection applications. Its AC/DC compatibility supports integration with suitable electrical systems, while the ABS case provides a practical housing for industrial installations. Cable options between 2 and 5 m allow convenient connection according to the required machine configuration. Designed for non-contact sensing, the E3JK Series photoelectric switch offers a practical solution for monitoring object presence, movement, and passage in compatible automated operations.
green checkCase Material : ABS
green checkType of Product : AC/DC Power-Free Type Photoelectric Switch
green checkSeries : E3JK Series
₹15,339 - ₹27,139
The Omron Small Electromagnetic Lock/Safety Door Switch D4NL Series is designed for dependable door monitoring and safety interlocking in industrial machinery and automated equipment. Operating at 50/60 Hz, this compact safety switch features a built-in 2NC slow-action contact arrangement combined with another 2NC slow-action configuration, providing reliable switching for machine guard and access-door applications. Its electromagnetic locking mechanism helps restrict access to hazardous machine areas during operation, supporting safer equipment control. The compact construction is suitable for installations where efficient use of panel and machine space is important. Engineered for industrial environments, the Omron D4NL Series offers a practical solution for safety circuits requiring consistent door-position detection and controlled access. The Omron Small Electromagnetic Lock/Safety Door Switch provides stable operation through its slow-action contact mechanism, helping deliver dependable switching as the protective door is opened or closed. The 2NC + 2NC contact configuration can be integrated into suitable safety control systems for monitoring machine access conditions. Its electromagnetic locking capability makes it applicable to production machinery, automated processing lines, manufacturing equipment, and guarded industrial systems. With its robust design and Omron engineering, the D4NL Series is a suitable choice for applications requiring reliable safety-door interlocking, monitoring, and machine protection.
green checkRated Frequency (Hz) : 50/60 Hz
green checkMechanical Durability : 1,000,000 Times or More
green checkType of Product : Small Electromagnetic Lock/Safety Door Switch
green checkSeries : D4NL Series
green checkMinimum Applicable Load : 5 V DC 1 mA Resistance Load
green checkBuilt in Switch : 2NC (Slow Action) + 2NC (Slow Action)
₹15,339 - ₹24,779
The Omron Small Electromagnetic Lock/Safety Door Switch 50/60 Hz, D4NL Series is a compact safety solution designed for reliable monitoring and interlocking of machine doors and protective guards. Featuring a built-in switch configuration with 1NC/1NO slow-action contacts plus 1NC/1NO slow-action contacts, this safety door switch supports dependable status detection during machine operation. Its electromagnetic locking function helps maintain controlled access to hazardous areas, making it suitable for industrial automation, machinery, and equipment safety applications. Designed for 50/60 Hz operation, the Omron D4NL Series combines practical functionality with a space-efficient construction for installation where panel space is limited. Built for consistent switching performance, the Omron Small Electromagnetic Lock/Safety Door Switch provides a dependable interface between machine access points and safety control systems. The slow-action contact mechanism enables stable switching during door movement, helping support accurate safety monitoring. Its compact electromagnetic lock design makes it suitable for manufacturing lines, processing equipment, automated machinery, and guarded industrial systems. With its established Omron engineering and versatile contact arrangement, the D4NL Series offers a practical choice for applications requiring reliable door position sensing and controlled access protection.
green checkRated Frequency (Hz) : 50/60 Hz
green checkMechanical Durability : 1,000,000 Times or More
green checkType of Product : Small Electromagnetic Lock/Safety Door Switch
green checkSeries : D4NL Series
green checkMinimum Applicable Load : 5 V DC 1 mA Resistance Load
green checkBuilt in Switch : 1NC/1NO (Slow Action) + 1NC/1NO (Slow Action)
₹15,339 - ₹31,859
Omron Electromagnetic Door Switch, Connector Connection Type, 6 Contact Configuration (In-built Switch: 3NC + 3NC) is engineered to provide reliable safety interlocking and accurate door position monitoring for industrial machinery and automated production systems. Designed with a connector connection type for quick installation and simplified maintenance, this electromagnetic door switch features a 6-contact configuration comprising two independent sets of three normally closed (NC) contacts. It is ideal for machine guards, safety gates, access doors, robotic systems, automated production lines, and industrial equipment where fail-safe safety monitoring is essential. Built to Omron’s globally trusted engineering standards, the Omron Electromagnetic Door Switch, Connector Connection Type, 6 Contact Configuration (In-built Switch: 3NC + 3NC) delivers stable switching performance, excellent mechanical durability, and long operational life under demanding industrial conditions. The connector-based design minimizes wiring time and enables fast replacement during maintenance, while the multiple NC contacts integrate seamlessly with safety relays, PLCs, and machine control systems. Trusted by engineers, automation specialists, and maintenance professionals, this Omron electromagnetic door switch enhances workplace safety, improves equipment reliability, and supports efficient industrial automation across a wide range of applications.
green checkRated Frequency (Hz) : 50/60 Hz
green checkMechanical Durability : 10 Million Times or More
green checkOperation Ambient Temperature : -10 to 55℃
green checkInsulation Resistance : 100 or more (with DC500V mega)
green checkMinimum Applicable Load : DC5V 1mA resistance load (N level reference value)
green checkAmbient Humidity to Use : 95% RH or less
green checkContact Resistance : 200 mΩ or Less
green checkIn-built Switch : 3NC+3NC
green checkConnection Type : Connector
green checkContact Configuration : 6 Contacts
green checkVibration Resistance (Malfunction) : 10~55Hz one amplitude 0.35mm
green checkRated Voltage (V) : DC24
₹16,519 - ₹25,959
The Omron Small Electromagnetic Lock/Safety Door Switch 50/60 Hz, 3NC (Slow Action) + 1NC/1NO (Slow Action) Built in Switch, D4NL Series is designed for reliable safety interlocking and protective door monitoring in industrial machinery. Its electromagnetic locking mechanism helps restrict access to guarded areas during machine operation, while the 3NC and 1NC/1NO slow-action contact configuration supports dependable switching across safety and control circuits. The compact construction makes it suitable for equipment where installation space is limited without compromising essential door monitoring functionality. This D4NL Series safety door switch provides a practical combination of electromagnetic locking and multi-contact switching for industrial safety applications. The Omron Small Electromagnetic Lock/Safety Door Switch 50/60 Hz, 3NC (Slow Action) + 1NC/1NO (Slow Action) Built in Switch, D4NL Series is suitable for automated machinery, production lines, processing equipment, and machine guarding systems. Its built-in slow-action contacts facilitate accurate safety door status detection and connection with machine control circuits. The electromagnetic locking feature helps maintain controlled access while equipment is active, supporting safer operating conditions. With its compact profile and versatile contact arrangement, this safety door switch offers dependable performance for industrial access control and machine safety requirements.
green checkRated Frequency (Hz) : 50/60 Hz
green checkMechanical Durability : 1,000,000 Times or More
green checkType of Product : Small Electromagnetic Lock/Safety Door Switch
green checkSeries : D4NL Series
green checkMinimum Applicable Load : 5 V DC 1 mA Resistance Load
green checkBuilt in Switch : 3NC (Slow Action) + 1NC/1NO (Slow Action)
₹11,327  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 3 ° max.
₹11,091  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹4,247  
Features:LoadGeneral loadRatings (AC): Non-Inductive loadRated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 480 VAC / Resistive load: 2 A(NC) 2 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO)Ratings (AC): Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 2.5 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 1.5 A(NO)Ratings (DC): Non-Inductive loadRated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.4 A(NC) 0.4 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO)Ratings (DC): Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Inductive load: 1.5 A(NC) 1.5 A(NO) / Motor load: 1.5 A(NC) 1.5 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.05 A(NC) 0.05 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.03 A(NC) 0.03 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class II (Grounding not required with double) insulation
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Permissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 2,000 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability500,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 300 m/s2 max.Movement DifferentialStandard value 0.5 mm max.
₹9,439  
Features:Electrical ratings4 A at 30 VDCLoadGeneral loadRatings (DC): Non-Inductive loadRated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)Ratings (DC): Inductive loadRated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 30 VDC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability110,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability1,000,000 operations min. (0.1 A at 30 VDC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 3 ° max.
₹8,967  
Features:Electrical ratings4 A at 30 VDCLoadGeneral loadRatings (DC): Non-Inductive loadRated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)Ratings (DC): Inductive loadRated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 30 VDC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability110,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability1,000,000 operations min. (0.1 A at 30 VDC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 3 ° max.
₹6,725  
Features:Electrical ratings4 A at 30 VDCLoadGeneral loadRatings (DC): Non-Inductive loadRated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)Ratings (DC): Inductive loadRated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 30 VDC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability110,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability1,000,000 operations min. (0.1 A at 30 VDC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹8,377  
Features:Electrical ratings4 A at 30 VDCLoadGeneral loadRatings (DC): Non-Inductive loadRated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)Ratings (DC): Inductive loadRated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 30 VDC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability110,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability1,000,000 operations min. (0.1 A at 30 VDC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹9,085  
Features:Electrical ratings5 A at 125 VACLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 125 VAC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 3 ° max.
₹9,439  
Features:Electrical ratings5 A at 125 VACLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)IndicatorVoltage: 125 VAC, LED (Light when not operating)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹8,377  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹7,433  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
₹10,501  
Features:Electrical ratings5 A at 250 VAC, 4 A at 30 VDCLoadGeneral loadRatings (AC) Non-Inductive loadRated voltage: 125 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1.5 A(NC) 0.7 A(NO)
Rated voltage: 250 VAC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 1 A(NC) 0.5 A(NO)Ratings (AC) Inductive loadRated voltage: 125 VAC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 2.5 A(NC) 1.3 A(NO)
Rated voltage: 250 VAC / Inductive load: 2 A(NC) 2 A(NO) / Motor load: 1.5 A(NC) 0.8 A(NO)Ratings (DC) Non-Inductive loadRated voltage: 8 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 14 VDC / Resistive load: 5 A(NC) 5 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.4 A(NC) 0.4 A(NO) / Lamp load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.2 A(NC) 0.2 A(NO) / Lamp load: 0.03 A(NC) 0.03 A(NO)Ratings (DC) Inductive loadRated voltage: 8 VDC / Inductive load: 5 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 14 VDC / Inductive load: 4 A(NC) 4 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.4 A(NC) 0.4 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.2 A(NC) 0.2 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)Protective circuitClassification of protection against electric shock: Class I (with earth wire)
Short-circuit protective device: 10 A fuse type gI or gG (IEC60269)Earth terminalWith earth wireCable specificationsVCTF oil-resistant cable, 3 mPermissible operating frequency Mechanically: 120 operations / 1 minute max., Electrically: 30 operations / 1 minute max.Dielectric strengthBetween each terminal of the same polarities: 1,000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 minImpulse withstand voltageBetween live-metallic part and ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kVMechanical durability10,000,000 operations min. (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Electrical durability200,000 operations min. (5 A at 125 VAC) (Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)Shock resistanceDestruction: 1000 m/s2 max., Malfunction: 500 m/s2 max.Movement DifferentialStandard value 0.2 mm max.
Recommended Items
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
21
Pack of 40 piece
₹110 ₹110
0.01% OFF
oos-available Ships within 24 hrs
sku-leadTime Ships within 10 days
oos-available Ships within 24 hrs
sku-leadTime Ships within 10 days
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
oos-available Ships within 24 hrs
Browsing History
sku-leadTime Ships within 5 days
sku-leadTime Ships within 7 days
sku-leadTime Ships within 3 days
sku-leadTime Ships within 7 days
sku-leadTime Ships within 10 days