View
View
View
View
| Type of Product | Multi-Circuit Energy Monitor Main Unit |
| Model No | BT3720KN1 |
| Country of Origin | Japan |
| Name of Manufacturer/Packer/Importer | Panasonic Corporation |
Warranty as per brand
100% Original Products
Secure payments
100% Buyer protection
Top Brands
Type of Product |
Multi-Circuit Energy Monitor Main Unit |
Model No |
BT3720KN1 |
Country of Origin |
Japan |
Name of Manufacturer/Packer/Importer |
Panasonic Corporation |
Color |
Gray |
Monotaro ID |
51504269 |
Import Country |
Direct Import from Japan |
Mass (g) |
300 *Does not include backup battery or SD memory card |
Specifications |
Pulse input Input method: No-voltage a contact or open collector (NPN) / Contact conditions: DC10V, 10mA or more / Open collector conditions: Leak current 1mA or less / Pulse conditions: Pulse ON, OFF time 30ms or more / Allowable chattering 3ms or less / Hourly 32000 pulses or less/Pulse input cable length extension: 100m or less (wire diameter 0.9 mm² or more) *"Weight" can be set in the range of 0.1 to 6553.5 (in 0.1 units). CT cable: 1/2/5/10/20/30/50m, pulse input cable: 9VA, maximum number of expansion units: 3 units in total (for one main unit, expansion units, different types of units, pulse total of output units), electrical specifications: RS-485 compliant, measurement elements: instantaneous power/integrated energy/voltage/current/power factor/number of pulses, clock accuracy: approximately ±1 minute/month difference (ambient temperature 25 ℃) |
Rated Input Voltage (V) |
Single-Phase Two-Wire, Single-Phase Three-Wire: 100/200, Three-Phase Three-Wire: 110, 220 |
Rated Power Consumption (W) |
10 |
Conditions to Use |
Temperature: -10 to +50℃, relative humidity: within 30 to 80% (no condensation) |
Phase / Wire Type |
Single-Phase 2-Wire/Single-Phase 3-Wire/Three-Phase 3-Wire: When Used, Use The Main Unit Alone, Or Add On To The Main Unit Or Combine Different Types Of System Units. You Can Increase The Number Of Power Supply Systems By Using Heterogeneous System Units. |
No. of Circuits |
Up To 16 Circuits Can Be Added To The Main Unit Or In Combination With Different Systems. All Circuits Can Be Replaced With Pulse Measurement. 4 Circuits For The Main Unit Alone, 4 Additional Circuits For Each Expansion Or Addition Of A Different Type Of Unit. For Single-Phase 2-Wire, The Number Of Circuits Is Doubled. It Cannot Be Doubled With Pulses. |
Power Outage Compensation Time |
200 |
Material |
ABS |
Allowable Voltage Range |
100-240 V (-15%, + 10%) (Shared With Power Supply) |
Communication Protocol |
Rs-485 2-Wire / 4-Wire |
Type |
Main unit |
Rated Power Consumption |
20 VA (Consumption Va Varies Depending On The Combination Specifications. Example Of 1 Main Unit + 3 Extensions + Display Setting Unit) |
Rated Input Current (A) |
/5, 5, 50, 100, 250, 400, 600, 30A easy-to-use breaker */5ACT is used in combination with a general-purpose CT with a secondary side rating of 5A, which must be prepared by the customer. |
Type of Sign |
IEC rail, articulated mounting plate, screw fastening |
Logging Capability |
Automatic logging: Measurement items "Hourly" Integrated power consumption and pulse integrated amount for each hour. "Daily" Total amount of power and pulse amount for each day. "Monthly" Total amount of electricity and pulse amount for each month. Collection The latest 65 days' data by hour, the latest 1 year's data by day, and the latest 3 years' data by month are saved in the internal memory. These can be displayed in the display configuration unit. Of the data saved in the internal memory of an SDHC/SD memory card, you can retrieve this month's and last month's data. Detailed logging: Measurement items: Instantaneous power, integrated energy, voltage, current, pulse integrated amount, collected every minute. The latest 1 day's worth (24 hours) is saved in the main unit's internal memory. It can be removed using an SDHC/SD memory card. |
Accuracy |
When using 50 to 600 ACT (model number suffix KN): Instantaneous power (kW) accuracy ±1.0% (relative to rated input)/integrated energy (kWh) accuracy ±1.0% (3.3 to 100% range of rated current, power factor) 1)/Voltage (V) accuracy ±1.0% (relative to rated input)/Current (A) accuracy ±1.0% (relative to rated input)/Power factor (%) accuracy ±3.0% (relative to rated input) ), /5A CT, 5A CT, when using CT for Cantouch bar with built-in Cantouch breaker CT: Instantaneous power (kW) accuracy ±2.0% (relative to rated input): Integrated power consumption (kWh) accuracy ±2.0% ( Range of 5.0 to 100% of rated current, power factor 1)/voltage (V) accuracy ±1.0% (relative to rated input)/current (A) accuracy ±1.0% (relative to rated input)/power factor (%) ) Accuracy ±3.0% (for rated input) |