| Type of Product | CPU Unit |
| Model No | AFP7CPS3RS |
| Program Memory | Built-in flash ROM (no backup battery required) |
| Standard | Product CE marking *CE marking is not displayed on cables and additional memory as they are not subject to applicable standards when used individually. When set with the PLC main unit, it complies with applicable directives. MC Directive Applicable Standard: EN61131-2, UL Registered Product (Listed) File No.: E96300 Standard No.: UL 61010-2-201, CSA Approved Product (Certified) File No.: E96300(C-UL) Standard No. :CAN/CSA-C22.2 No.61010-2-201 |
Warranty as per brand
100% Original Products
Secure payments
100% Buyer protection
Top Brands
Type of Product |
CPU Unit |
Model No |
AFP7CPS3RS |
Program Memory |
Built-in flash ROM (no backup battery required) |
Standard |
Product CE marking *CE marking is not displayed on cables and additional memory as they are not subject to applicable standards when used individually. When set with the PLC main unit, it complies with applicable directives. MC Directive Applicable Standard: EN61131-2, UL Registered Product (Listed) File No.: E96300 Standard No.: UL 61010-2-201, CSA Approved Product (Certified) File No.: E96300(C-UL) Standard No. :CAN/CSA-C22.2 No.61010-2-201 |
Interface |
RS-232C 3-wire 1CH *Terminals SD, RD, and SG are isolated from the internal circuit. |
Monotaro ID |
51702588 |
Shock Resistance |
147 m/s² or more 3 times in each direction of XYZ (IEC 61131-2) |
Protocol |
Stop bit: 1bit/2bit, Parity: No/Yes (odd/even), Data length: 7bit/8bit, Start code: With STX/No STX, End code: CR/CR+LF/No/ETX, Data transmission order: Send from bit 0 in character units |
Synchronization Type |
Asynchronous method |
Country of Origin |
Japan |
Import Country |
Direct Import from Japan |
Communication Protocol |
Half-duplex method |
Function |
Internal relay (R): 32768 points, System relay (SR): Various relays that indicate the status of internal operation, Link relay (L): 16384 points, Timer (T): 4096 points (10μs, 1ms, 10ms, 100ms, Counter (C): 1024 points, can count from 1 to 4294967295, Link data register (LD): 16384 words, System data register (SD): Various registers that indicate the status of internal operation, etc. Index register (I0 to IE): 15 long words/with switching function, Master control relay (MCR): No limit, Number of labels (LOOP): Maximum 65535 for each PB, Number of differential points: No limit, Number of step ladder: Limited None, Number of subroutines: Up to 65535 for each PB, Number of interrupt programs: 1 (constant cycle program), SD memory card function: Up to 32GB of SDHC can be used, Constant scan: Possible (0 to 125ms), Calendar timer: Year (2 digits of the Western calendar), month, date, hour (24-hour display), minute, second, day of the week *Calendar accuracy 0℃: Monthly difference of 95 seconds or less, 25℃: Monthly difference of 15 seconds or less, 55℃: Monthly difference of 130 seconds below. Battery life (value when completely de-energized): 3.3 years or more [Actual usage value: approximately 20 years (25℃)], Security functions: Password/Limited distribution/Read prohibition setting/Encryption, PLC link function: Up to 16 units , link relay 1024 points, link register 128 words (data transfer and remote programming are not possible) (link area allocation can be switched between the first half and the second half) |
Atmosphere |
No corrosive gas. There should be no excessive dust. |
Noise Resistance |
1000V[PP] pulse width 50ns, 1 μs (by noise simulator method) |
Control |
Cyclic calculation method |
External Output |
Y: 8192 points *The number of points that can be used as actual I/O is limited by the hardware. Can be used as an internal relay when not used as actual I/O. |
RoHS Directive |
Correspondence |
Program Memory Capacity |
Memory selection pattern 1 Program (step): 121500 Data register (word): 131072 Maximum number of PB: 243 *Pattern 1 is selected at the time of shipment. *Up to 262,144 words of DT can be backed up. Memory selection pattern 2 Program (step): 96000 Data register (word): 262144 Maximum number of PB: 192 *Up to 262144 words of DT can be backed up. Memory selection pattern 3 Program (step): 64000 Data register (word): 425984 Maximum number of PB: 128 *Up to 262144 words of DT can be backed up. Memory selection pattern 4 Program (step): 32000 Data register (word): 589824 Maximum number of PB: 64 *Up to 262144 words of DT can be backed up. |
Name of Manufacturer/Packer/Importer |
Panasonic Corporation |
Terminal |
Terminal 5V: For DC5V type GT series *5V and 24V cannot be used at the same time. Terminal 24V: For DC24V type GT series *5V and 24V cannot be used at the same time. *Please use the power supply of the CPU unit at DV 21.6V to 26.4V. Please check the GT series hardware manual for grounding of the GT display unit. |
Current Consumption (mA) |
200 or less |
Operation Ambient Temperature (°C) |
0 to +55, when saving: -40 to +70 |
Mass of Main Unit (g) |
Approximately 220 (including terminal block and end unit) |
External Input |
X: 8192 points *The number of points that can be used as actual I/O is limited by the hardware. Can be used as an internal relay when not used as actual I/O. |
Transmission Speed (bps) |
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 |