| Type of Product | Soft start/quick exhaust valve |
| Size | 6 |
| Suitable For | See supplementary material information |
| Part No | 548713 |
Type of Product |
Soft start/quick exhaust valve |
Size |
6 |
Suitable For |
See supplementary material information |
Part No |
548713 |
Country of Origin |
Germany |
Series |
MS |
Duty Cycle |
100% |
Item Code |
MS6(N)-SV |
Name of Manufacturer/Packer/Importer |
D.K. DIES AND TOOLS |
Seal Material |
NBR |
Pressure Gauge |
Prepared for G1/4Prepared for G1/8Red/green scale With pressure sensor With pressure sensor With LCD display With pressure sensor With operational status indicator With pressure gauge |
Design |
Piston Gate Valvepiston Seat |
Mounting Type |
Either:Inline installationWith accessories |
Approval |
RCMc UL us - Recognised (Oil) |
Ambient Temperature |
-10 °C - 60 °C |
Operating Pressure |
0.3 MPa - 1 MPa |
Valve Function |
3/2-way, single solenoid, closedSoft-start function |
Note on Materials |
RoHS compliant |
Housing Material |
Die-Cast Aluminium |
Labs (Pwis) Conformity |
VDMA24364-B1/B2-L |
Mounting position |
Any |
Standard nominal flow rate |
4300 l/min - 5700 l/min |
Note on Operating and Pilot Medium |
Lubricated operation possible (in which case lubricated operation will always be required) |
Operating Medium |
Compressed air to ISO 8573-1:2010 [7:4:4] |
Media Temperature |
-10 °C - 60 °C |
Corrosion Resistance Class crc |
2 - Moderate corrosion stress |
Storage Temperature |
-10 °C - 60 °C |
Piston Rod Material |
High-alloy stainless steel |
Grid Size |
62 mm |
Actuation Type |
Electrical |
Ukca Marking |
To UK regulations for machinesTo UK RoHS instructions |
Protection Degree |
IP65With plug socket |
Manual Override |
NoneOn pilot solenoid valves: non-detenting; on soft-start/quick exhaust valve: detenting, self-resettingOn pilot solenoid valves: non-detenting, detenting; on soft-start/quick exhaust valve: detenting, self-resetting |
CE |
To EU EMC DirectiveTo EC Machinery DirectiveTo EU Low Voltage DirectiveIn accordance with EU RoHS Directive |
Kc Mark |
KC-EMV |
Signal Status Display |
Potential-free contact Switching outputs |
Forced Dynamization |
Switching frequency min. 1/month |
Type of Resetting |
Mechanical spring |
Pilot |
Piloted |
Sealing Principle |
Soft |
Certification |
01/205/5999.06/26 |
Exhaust Air Function |
Cannot be throttled |
Shock Resistance |
Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 |
Characteristic Coil Data |
230 V AC: 50/60 Hz, pick-up power 3.0 VA, holding power 2.4 VA24 V DC: 1.5 W24 V DC: 1.8 W |
Safety Functions |
Exhaust Prevention of unexpected start-up (pressurisation) |
Vibration Resistance |
Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 |
Pilot Air Supply |
Internal |