| Storage Temperature | -25 to 65 (no condensation or freezing) |
| Type of Product | Temperature Controller |
| Input Type | Thermocouple / resistance temperature detector / sensor / current / voltage |
| Model No | E5CC-CQ3ASM-005 |
Storage Temperature |
-25 to 65 (no condensation or freezing) |
Type of Product |
Temperature Controller |
Input Type |
Thermocouple / resistance temperature detector / sensor / current / voltage |
Model No |
E5CC-CQ3ASM-005 |
Control Output |
Linear current output / voltage output (for SSR drive) |
Character Height (mm) |
PV:15.2, SV:7.1 |
Monotaro ID |
66478746 |
Power Supply Voltage |
AC 100 to 240 V (50/60 Hz) |
Input Impedance |
Current input 150 Ω or less, voltage input 1M or more (When connecting ES2-HB-N/THB-N, use a 1:1 connection.) |
Mass (g) |
Main unit: Approx. 120, Mounting adapter: Approx. 10 |
Applicable Standard |
EN 61010-1(IEC 61010-1), RCM |
Shape |
Din 48x48 |
Terminal Shape |
Screw terminal block |
Country of Origin |
INDONESIA |
Control |
ON/OFF or 2 degrees of freedom PID (with auto tuning) |
Import Country |
Direct Import from Japan |
Pattern Setting |
Digital setting with front keys |
Standard |
[Certification standards] cULus: UL 61010-1/CSA C22.2 No.61010-1, KOSHA (S mark) certification (some models only), Korea Radio Regulations (Radio Act: KC mark) (some models only), Lloyd's standard |
Protection Class |
Front: IP66, Rear case: IP20, Terminal part: IP00 |
Operating Temperature Range |
-10 to 55 ℃ (no condensation or freezing) / 3-year warranty: -10 to 50 ℃ (no condensation or freezing) when installed as standard |
Name of Manufacturer/Packer/Importer |
Omron Corporation |
Specifications |
●Multi-SP function: Up to eight target values (SP0 to SP7) can be stored and selected by event input, key operation, or serial communication●Recommended fuse: T2A, AC250V time-lag low breaking capacity●Installation environment: Overvoltage category II, pollution degree 2 (EN/IEC/UL 61010-1)●Effects of electromagnetic interference (according to EN 61326-1): Thermocouple input (R, S, B, C/W, PLⅡ): (±1% of indicated value or ±10°C, whichever is greater) ±1 digit or less Other thermocouple input: (±1% of indicated value or ±4°C, whichever is greater) ±1 digit or less Platinum resistance thermometer input: (±1% of indicated value or ±2°C, whichever is greater) ±1 digit or less Analog input: ±1%FS ±1 digit or less, CT input: ±5%FS ±1 digit or less Remote SP input: ±1%FS ±1 digit or less Manual reset value: 0.0 to 100.0% (in 0.1% increments) Configuration tool port: Top: Use the USB-serial conversion cable E58-CIFQ2 to connect to the USB port on the PC |
Other functions |
Manual output, heating/cooling control, loop break alarm function, SP lamp, alarm function, heater break detection function (including SSR failure), 40% AT, 100% AT, operation amount limit, input digital filter, self-tuning, robust tuning, PV input correction, run/stop, protect, square root calculation function, operation amount change rate limit, simple calculation, temperature status display function, simple program function, input moving average, display brightness setting |