Your Free Gift is Awaiting in your Inbox
Features |
|
Brand Name : | Schneider Electric |
Type of Product : | Multifunction Meter |
Model No : | METSEEM6400NGRSCL1 |
Accuracy Class : | 1 |
Voltage Measurement : | ±0.5% |
Current Measurement : | ±0.5% |
More Details |
-
Warranty
12 months manufacturer warranty -
100% Original
Products -
Free Shipping
on orders above Rs. 1,000 -
Secure
Payments -
100% buyer
Protection -
EARN
IB Coins -
7 days
Returnable
Current | Average line current of 3-phase, per-phase, and calculated neutral current |
Voltage | Average voltage of L-L, L-N parameters, and per-phase |
Frequency | Any available line |
Real, reactive, and apparent power | Total and per-phase value |
Displacement power factor | Average and per-phase signed, four-quadrant |
True power factor | Average and per-phase signed, four-quadrant |
Demand values
Current average | Present, Last, Predicted, Peak, and Peak Date Time |
Active power | Present, Last, Predicted, Peak, and Peak Date Time |
Reactive power | Present, Last, Predicted, Peak, and Peak Date Time |
Apparent power | Present, Last, Predicted, Peak, and Peak Date Time |
Demand sync methods | Thermal, Timed, Command Sync, and Clocked Sync |
Demand calculation mode | Sliding, fixed and rolling block |
Electrical characteristics
Type of measurement Measurement accuracy | True RMS, 64 samples per cycle |
Current, Phase | ±0.5% |
Voltage L-N, L-L | ±0.5% |
Power Factor | ±0.01 |
Power | ±0.5% |
Frequency | ±0.05% |
Real Energy | Class 0.5S and Class 0.2*1 as per IEC 62053-22 and Class 1.0 as per IEC 62053-21 for both CT nominal of 5 A and 1 A*2 |
Reactive Energy | IEC 62053-23 Class 2 |
THD and Individual Harmonic, V& A Input-voltage | Class 5.0 as per IEC 61557-12 for THD and individual harmonics up to 15th |
VT primary | 999 kV L-L max, starting voltage depends on VT ratio |
U nominal | 277 V L-N/480V L-L |
Measured V with full range | 35 to 600 VAC L-L |
Permanent overload | 750 VAC L-L |
Impedance | => 5 MO |
Frequency range | 50/60 Hz +/-5% |
VA burden | < 0.2 VAat 240 VAC L-N |
Input-current CT ratings | Primary adjustable 1 A to 32768 A Secondary 1A or 5 A l-nominal |
Measured Amps with over range & Crest Factor | 5mAto6A |
Withstand | Continuous 12 A, 50 A at 10 sec/hr |
Impedance | <0.3 MO |
Frequency range | 50/60 Hz +1-5% |
VA Burden AC control power | <0.1 VAat6A |
Operating range | 44- 277 VAC ±10% |
Burden | < 6 VA at 277 V L-N |
Frequency | 50/60 Hz nominal |
Ride-through time DC control power | 100 ms typical at 120 V AC and maximum burden 100 ms typical at 277 V AC and maximum burden |
Operating range | 44-277 V DC ±10% |
Burden | < 2 Wat 277 V DC |
Ride-through time Real time clock | 50 ms typical at 125 V DC and maximum burden |
Ride-through time Displays update | 3 years |
Instantaneous | 1 s |
Demand | 15s |
Harmonics | 5s |
Mechanical characteristics
Weight | ~600gms (21 oz) |
IP degree of protection | (IEC 60529) IP51 front display, IP30 meter body |
Material | Polycarbonate meets UL94V-0 flammability rating |
Dimensions Wx H x D | 96 x 96 x 73 mm (3.78 x 3.78 x 2.87 in) maximum (depth of the meter from housing mounting flange) and 13 mm (0.51 in) (protrusion of meter from housing flange) |
Mounting position | Vertical |
Panel thickness | 5 mm (0.196 in) maximum |
Operating temperature | Meter -10.. +60 °C (+14...+140 °F) |
Storage temperature | Meter -20...+70 °C (-4...+158 °F) |
Humidity rating | 5 to 95% RH at 50 °C (122 °F) (non-condensing) |
Pollution degree | 2 |
Altitude | 2000 m (6561 ft) Category III |
Product life | > 7 years |
EM6400NG multi-function meter display overview
A | Phase measurements | VL-N, VL-L, I, kVA, kW, kVAR, PF, VTHD, ITHD |
B | Demand measurements | DM, PrsDM, PrdDM, MD |
C | RTC | Date and time |
D | Negative indicator | |
E | Navigation key | To navigate down |
F | Energy readings | Apparent energy, Active energy, and Reactive energy |
G | Navigation key | To navigate up |
H | OK | Enter key |
I | Energy pulsing LED (Red), Heartbeat/communications LED (Green) | |
J | x 1000 indicator | |
K | System measurements | Vavg, kVA, F, lavg, kW, In, PFavg, kVAR, lunb |
L | Retainer clip | |
M | Input current terminals | A1 (S1, S2), A2 (S1, S2), A3 (S1, S2) |
N | RS-485 communications/ POP terminals | D1+, DO- |
O | Protective cover | |
P | Auxiliary power supply (control power) terminals | L+, N- |
Q | Input voltage terminals | V1, V2, V3, VN |
Buy Schneider Multi-Function Meter Accuracy 1 METSEEM6400NGRSCL1 online in India at wholesale rates. If you have been looking for Schneider Multi-Function Meter Accuracy 1 METSEEM6400NGRSCL1 dealers, your search ends here as you can get the best Schneider Multi-Function Meter Accuracy 1 METSEEM6400NGRSCL1 distributors in top cities such as Delhi NCR, Mumbai, Chennai, Bengaluru, Kolkata, Chennai, Pune, Jaipur, Hyderabad and Ahmedabad. You can purchase Schneider Multi-Function Meter Accuracy 1 METSEEM6400NGRSCL1 of the finest quality and rest assured to get the best in terms of both durability and performance. If you are bothered about the Schneider Multi-Function Meter Accuracy 1 METSEEM6400NGRSCL1 prices, you can be totally sure to get the best rates as Industrybuying brings you genuine Schneider Multi-Function Meter Accuracy 1 METSEEM6400NGRSCL1 rates and quality assured products only from the best of brands with exclusive brand discounts you won’t find anywhere else. Procure Schneider Multi-Function Meter Accuracy 1 METSEEM6400NGRSCL1 today and avail the best offers on your purchase.
10,089
(GST inclusive price)
8,550
(GST extra)
45.71% OFF
|