Industry Buying is India's largest marketplace for Industrial Goods, Business Supplies, MRO Products, Tools, Equipment and many more. Wholesale Price, 7 Days Return, COD.
Welcome to our New website!
Shop By Category
Rated Output Current (A) | 23.8 (22.5) <br> (Caution) When the ambient temperature is over 40 ° C and the carrier frequency is 3kHz or more, select the inverter so that the continuous operation current is less than the rated current in parentheses. <br> If the carrier frequency is set low, the motor temperature may increase and the inverter's protective operation (current limiting operation) may be applied. When operating at a carrier frequency of 1 kHz or less, select an inverter with a rated output current of 80%. |
Output Overload Current Rating | 120% -1min of rated output current |
Required Capacity for Input Power (kVA) | 7.4 <br> (Caution) Indicates the value when DC reactor (DCR) is applied. |
Allowable Fluctuation of Voltage | +10 to -15% (correlation unbalance rate within 2%) |
Rated Output Current (A) |
23.8 (22.5) <br> (Caution) When the ambient temperature is over 40 ° C and the carrier frequency is 3kHz or more, select the inverter so that the continuous operation current is less than the rated current in parentheses. <br> If the carrier frequency is set low, the motor temperature may increase and the inverter's protective operation (current limiting operation) may be applied. When operating at a carrier frequency of 1 kHz or less, select an inverter with a rated output current of 80%. |
Output Overload Current Rating |
120% -1min of rated output current |
Required Capacity for Input Power (kVA) |
7.4 <br> (Caution) Indicates the value when DC reactor (DCR) is applied. |
Allowable Fluctuation of Voltage |
+10 to -15% (correlation unbalance rate within 2%) |
Safety Standard |
UL508C, C22.2No.14, EN50178: 1997 (pending) |
Power Supply |
3-phase 200-240V (with AVR function) <br> (Caution) A voltage higher than the power supply voltage cannot be output. |
Mass (Kg) |
3.4 |
Output Rated Frequency (Hz) |
50/60 |
DC Braking |
Braking start frequency: 0.0 to 60.0Hz Braking time: 0.0 to 30.0s Braking level: 0 to 60% |
Cooling Method |
Fan cooling |
Braking Torque |
20% <br> (Caution) This is the average braking torque for the motor alone. (Varies depending on motor efficiency) |
Motor Capacity |
5.5 |
Protection Class |
IP20 closed type |
Frequency Tolerance |
+5~-5% |
Monotaro ID |
8489826 |
Rated Output Capacity (kVA) |
8.3 <br> (Caution) The rated capacity is for 220V rating. |
Type of Product |
Inverters Main Units |
Frequency |
50-60 Hz |
No. of Phases |
Three Phase |
Country of Origin |
Japan |
Supply Voltage |
200-240 V |
Import Country |
Japan |
Name of Manufacturer/Packer/Importer |
Fuji Electric Co Ltd |